دورية أكاديمية

Green analytical toxicology method for determination of synthetic cathinones in oral fluid samples by microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.

التفاصيل البيبلوغرافية
العنوان: Green analytical toxicology method for determination of synthetic cathinones in oral fluid samples by microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.
المؤلفون: da Cunha KF; Campinas Poison Control Center, Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, 13083‑859, Brazil.; Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, 13083‑859, Brazil., Oliveira KD; Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, 13083‑859, Brazil., Costa JL; Campinas Poison Control Center, Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, 13083‑859, Brazil. jose.jlc@fcf.unicamp.br.; Faculty of Pharmaceutical Sciences, University of Campinas, Campinas, São Paulo, 13083‑859, Brazil. jose.jlc@fcf.unicamp.br.
المصدر: Forensic toxicology [Forensic Toxicol] 2024 Jan; Vol. 42 (1), pp. 18-30. Date of Electronic Publication: 2023 Jul 28.
نوع المنشور: Journal Article; Research Support, Non-U.S. Gov't; Comment
اللغة: English
بيانات الدورية: Publisher: Japanese Association of Forensic Toxicology Country of Publication: Japan NLM ID: 101315563 Publication Model: Print-Electronic Cited Medium: Print ISSN: 1860-8965 (Print) Linking ISSN: 18608965 NLM ISO Abbreviation: Forensic Toxicol Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Tokyo : Japanese Association of Forensic Toxicology : Springer, 2006-
مواضيع طبية MeSH: Synthetic Cathinone* , Tandem Mass Spectrometry*/methods, Chromatography, Liquid/methods ; Solid Phase Microextraction/methods ; Limit of Detection
مستخلص: Purpose: We developed and validated a method for quantitative analysis of ten synthetic cathinones in oral fluid (OF) samples, using microextraction by packed sorbent (MEPS) for sample preparation followed by liquid chromatography‒tandem mass spectrometry (LC‒MS/MS).
Method: OF samples were collected with a Quantisal™ device and 200 µL was extracted using a C18 MEPS cartridge installed on a semi-automated pipette and then analyzed using LC‒M/SMS.
Results: Linearity was achieved between 0.1 and 25 ng/mL, with a limit of detection (LOD) of 0.05 ng/mL and a limit of quantification (LOQ) of 0.1 ng/mL. Imprecision (% relative standard deviation) and bias (%) were better than 11.6% and 7.5%, respectively. The method had good specificity and selectivity against 9 different blank OF samples (from different donors) and 68 pharmaceutical and drugs of abuse with concentrations varying between 400 and 10,000 ng/mL. No evidence of carryover was observed. The analytes were stable after three freeze/thaw cycles and when kept in the autosampler (10 °C) for up to 24 h. The method was successfully applied to quantify 41 authentic positive samples. Methylone (mean 0.6 ng/mL, median 0.2 ng/mL), N-ethylpentylone (mean 16.7 ng/mL, median 0.35 ng/mL), eutylone (mean 39.1 ng/mL, median 3.6 ng/mL), mephedrone (mean 0.5 ng/mL, median 0.5 ng/mL), and 4-chloroethcathinone (8.1 ng/mL) were quantified in these samples.
Conclusion: MEPS was an efficient technique for Green Analytical Toxicology purposes, which required only 650 µL organic solvent and 200 µL sodium hydroxide, and the BIN cartridge had a lifespan of 100 sample extractions.
(© 2023. The Author(s), under exclusive licence to Japanese Association of Forensic Toxicology.)
التعليقات: Comment on: J Anal Toxicol. 2022 Aug 13;46(7):705-711. (PMID: 34592764)
References: Kahl JMM, da Cunha KF, Rodrigues LC, Chinaglia KO, Oliveira KD, Costa JL (2021) Quantification of amphetamine and derivatives in oral fluid by dispersive liquid-liquid microextraction and liquid chromatography–tandem mass spectrometry. J Pharm Biomed 196:113928. https://doi.org/10.1016/j.jpba.2021.113928. (PMID: 10.1016/j.jpba.2021.113928)
Moein MM, Abdel-Rehim A, Abdel-Rehim M (2015) Microextraction by packed sorbent (MEPS). TrAC Trends Anal Chem 67:34–44. https://doi.org/10.1016/j.trac.2014.12.003. (PMID: 10.1016/j.trac.2014.12.003)
Abdel-Rehim M (2011) Microextraction by packed sorbent (MEPS): a tutorial. Anal Chim Acta 701(2):119–128. https://doi.org/10.1016/j.aca.2011.05.037. (PMID: 10.1016/j.aca.2011.05.03721801877)
Desrosiers NA, Huestis MA (2019) Oral fluid drug testing: analytical approaches, issues and interpretation of results. J Anal Toxicol 43(6):415–443. https://doi.org/10.1093/jat/bkz048 . (open access article). (PMID: 10.1093/jat/bkz04831263897)
Mohr ALA, Friscia M, Yeakel JK, Logan BK (2018) Use of synthetic stimulants and hallucinogens in a cohort of electronic dance music festival attendees. Forensic Sci Int 282:168–178. https://doi.org/10.1016/j.forsciint.2017.11.017. (PMID: 10.1016/j.forsciint.2017.11.01729216523)
The European Monitoring Centre for Drugs and Drug Addiction-EMCDDA (2022) European drug report—trends and developments. p 60. https://www.emcdda.europa.eu/publications/edr/trends-developments/2022_en . Accessed 15 Apr 2023.
Pieprzyca E, Skowronek R, Czekaj P (2022) Toxicological analysis of intoxications with synthetic cathinones. J Anal Toxicol 46(7):705–711. https://doi.org/10.1093/jat/bkab102 . (open access article). (PMID: 10.1093/jat/bkab10234592764)
Nakamura M, Takaso M, Takeda A, Hitosugi M (2022) A fatal case of intoxication from a single use of eutylone: clinical symptoms and quantitative analysis results. Leg Med 58:102085. https://doi.org/10.1016/j.legalmed.2022.102085. (PMID: 10.1016/j.legalmed.2022.102085)
Hobbs JM, DeRienz RT, Baker DD, Shuttleworth MR, Pandey M (2022) Fatal intoxication by the novel cathinone 4-fluoro-3-methyl-α-PVP. J Anal Toxicol 46(3):e101-104. https://doi.org/10.1093/jat/bkac003 . (open access article). (PMID: 10.1093/jat/bkac00335020879)
da Cunha KF, Oliveira KD, Huestis MA, Costa JL (2020) Screening of 104 new psychoactive substances (NPS) and other drugs of abuse in oral fluid by LC-MS-MS. J Anal Toxicol 44(7):697–707. https://doi.org/10.1093/jat/bkaa089 . (open access article). (PMID: 10.1093/jat/bkaa08932685960)
da Cunha KF, Oliveira KD, Cardoso MS, Arantes ACF, Coser PHP, Lima LN, Maluf ACS, Comis MAC, Huestis MA, Costa JL (2021) Prevalence of new psychoactive substances (NPS) in Brazil based on oral fluid analysis of samples collected at electronic music festivals and parties. Drug Alcohol Depend 227:108962. https://doi.org/10.1016/j.drugalcdep.2021.108962 . (open access article). (PMID: 10.1016/j.drugalcdep.2021.10896234461412)
Brazilian Federal Police (2022) 2020 report—Synthetic drugs. https://www.gov.br/pf/pt-br/acesso-a-informacao/acoes-e-programas/relatorio-de-drogas-sinteticas-2020/relatorio_drogas_sinteticas_2020.pdf . Accessed 15 Apr 2023.
Warrick BJ, Wilson J, Hedge M, Freeman S, Karen L, Aaron C (2012) Lethal serotonin syndrome after methylone and butylone ingestion. J Med Toxicol 8:65–68. https://doi.org/10.1007/s13181-011-0199-6 . (open access article). (PMID: 10.1007/s13181-011-0199-622160789)
Deville M, Fedorowicz R, Grandjean F, Simon M, Charlier C (2022) Synthetic cathinones in Belgium: two case reports with different outcomes observed in the emergency room. J Anal Toxicol 46(9):e291–e295. https://doi.org/10.1093/jat/bkac092. (PMID: 10.1093/jat/bkac092)
Pieprzyca E, Skowronek R, Czekaj P (2022) Toxicological analysis of cases of mixed poisonings with synthetic cathinones and other drugs of abuse. J Anal Toxicol 46(9):1008–1015. https://doi.org/10.1093/jat/bkab119. (PMID: 10.1093/jat/bkab119)
Rocchi R, Simeoni MC, Montesano C, Vannutelli G, Curini R, Sergi M, Compagnone D (2018) Analysis of new psychoactive substances in oral fluids by means of microextraction by packed sorbent followed by ultra-high-performance liquid chromatography-tandem mass spectrometry. Drug Test Anal 10(5):865–873. https://doi.org/10.1002/dta.2330. (PMID: 10.1002/dta.233029078252)
ANSI/ASB Standard 036 (2019) Standard practices for method validation in forensic toxicology. p 46. https://www.aafs.org/sites/default/files/media/documents/036_Std_e1.pdf . Accessed 15 Apr 2023.
Said R, Pohanka A, Abdel-Rehim M, Beck O (2012) Determination of four immunosuppressive drugs in whole blood using MEPS and LC–MS/MS allowing automated sample work-up and analysis. J Chromatogr B 897:42–49. https://doi.org/10.1016/j.jchromb.2012.04.006. (PMID: 10.1016/j.jchromb.2012.04.006)
Ares AM, Fernández P, Regenjo M, Fernández AM, Carro AM, Lorenzo RA (2017) A fast bioanalytical method based on microextraction by packed sorbent and UPLC–MS/MS for determining new psychoactive substances in oral fluid. Talanta 174:454–461. https://doi.org/10.1016/j.talanta.2017.06.022. (PMID: 10.1016/j.talanta.2017.06.02228738608)
Sorribes-Soriano A, Sánchez-Martínez S, Arráez-González R, Esteve-Turrillas FA, Armenta S (2020) Methylone determination in oral fluid using microextraction by packed sorbent coupled to ion mobility spectrometry. Microchem J 153:104504. https://doi.org/10.1016/j.microc.2019.104504. (PMID: 10.1016/j.microc.2019.104504)
Bianchi F, Agazzi S, Riboni N, Erdal N, Hakkarainen M, Ilag LL, Anzillotti L, Andreoli R, Matezza F, Moroni F, Cecchi R, Careri M (2019) Novel sample-substrates for the determination of new psychoactive substances in oral fluid by desorption electrospray ionization-high resolution mass spectrometry. Talanta 202:136–144. https://doi.org/10.1016/j.talanta.2019.04.057. (PMID: 10.1016/j.talanta.2019.04.05731171161)
Miller B, Kim J, Concheiro M (2017) Stability of synthetic cathinones in oral fluid samples. Forensic Sci Int 274:13–21. https://doi.org/10.1016/j.forsciint.2016.11.034. (PMID: 10.1016/j.forsciint.2016.11.03427916403)
Amanda L.A. Mohr, Melissa Friscia BK, Logan (2016) Identification and prevalence determination of novel recreational drugs and discovery of their metabolites in blood, urine and oral fluid. In: U.S. Dep. Justice. https://www.ojp.gov/ncjrs/virtual-library/abstracts/identification-and-prevalence-determination-novel-recreational . Accessed 20 Jun 2023.
de Castro A, Lendoiro E, Fernández-Vega H et al (2014) Liquid chromatography tandem mass spectrometry determination of selected synthetic cathinones and two piperazines in oral fluid. Cross reactivity study with an on-site immunoassay device. J Chromatogr A 1374:93–101. https://doi.org/10.1016/j.chroma.2014.11.024. (PMID: 10.1016/j.chroma.2014.11.02425482853)
Pascual-Caro S, Borrull F, Calull M, Aguilar C (2021) A fast analytical method for determining synthetic cathinones in oral fluid by liquid chromatography–tandem mass spectrometry. J Anal Toxicol 45:693–700. https://doi.org/10.1093/jat/bkaa144 . (open access article). (PMID: 10.1093/jat/bkaa14433031561)
Di Trana A, Mannocchi G, Pirani F, La Maida N, Gottardi M, Pichini S, Busardò FP (2020) A comprehensive HPLC–MS-MS screening method for 77 new psychoactive substances, 24 classic drugs and 18 related metabolites in blood, urine and oral fluid. J Anal Toxicol 44(8):769–783. https://doi.org/10.1093/jat/bkaa103 . (open access article). (PMID: 10.1093/jat/bkaa10332816015)
Krotulski AJ, Mohr ALA, Fogarty MF, Logan BK (2018) The detection of novel stimulants in oral fluid from users reporting ecstasy, Molly and MDMA ingestion. J Anal Toxicol 42(8):544–553. https://doi.org/10.1093/jat/bky051 . (open access article). (PMID: 10.1093/jat/bky05130371847)
Poyatos L, Papaseit E, Olesti E et al (2021) A comparison of acute pharmacological effects of methylone and MDMA administration in humans and oral fluid concentrations as biomarkers of exposure. Biology (Basel) 10:788. https://doi.org/10.3390/biology10080788 . (open access article). (PMID: 10.3390/biology1008078834440023)
Sprega G, Di Giorgi A, Poyatos L et al (2023) Usefulness of oral fluid for measurement of methylone and its metabolites: correlation with plasma drug concentrations and the effect of oral fluid pH. Metabolites 13:468. https://doi.org/10.3390/metabo13040468 . (open access article). (PMID: 10.3390/metabo130404683711012710143603)
معلومات مُعتمدة: 2018/00432-1 Fundação de Amparo à Pesquisa do Estado de São Paulo; 2018/11849-0 Fundação de Amparo à Pesquisa do Estado de São Paulo; 2020/10809-5 Fundação de Amparo à Pesquisa do Estado de São Paulo; 2017/02147-0 Fundação de Amparo à Pesquisa do Estado de São Paulo; 001 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior; 88887.516176/2020-00 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
فهرسة مساهمة: Keywords: Green analytical toxicology (GAT); LC–MS/MS; Microextraction by packed sorbent (MEPS); Oral fluid; Synthetic cathinones
المشرفين على المادة: 0 (Synthetic Cathinone)
تواريخ الأحداث: Date Created: 20230728 Date Completed: 20240125 Latest Revision: 20240216
رمز التحديث: 20240216
DOI: 10.1007/s11419-023-00671-z
PMID: 37505359
قاعدة البيانات: MEDLINE
الوصف
تدمد:1860-8965
DOI:10.1007/s11419-023-00671-z