دورية أكاديمية

Device implantation complicated by a retrosternal goiter.

التفاصيل البيبلوغرافية
العنوان: Device implantation complicated by a retrosternal goiter.
المؤلفون: Elshafie S; Cardiology Department, University Hospitals of Derby and Burton, Derby, UK., Tariq AT; Cardiology Department, University Hospitals of Derby and Burton, Derby, UK., Leon FL; Cardiology Department, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.
المصدر: Pacing and clinical electrophysiology : PACE [Pacing Clin Electrophysiol] 2024 May; Vol. 47 (5), pp. 673-675. Date of Electronic Publication: 2023 Aug 18.
نوع المنشور: Case Reports; Journal Article
اللغة: English
بيانات الدورية: Publisher: Futura Pub. Co. Country of Publication: United States NLM ID: 7803944 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1540-8159 (Electronic) Linking ISSN: 01478389 NLM ISO Abbreviation: Pacing Clin Electrophysiol Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Mount Kisco, N. Y. : Futura Pub. Co., c1978-
مواضيع طبية MeSH: Pacemaker, Artificial*, Humans ; Male ; Goiter, Substernal/surgery ; Goiter, Substernal/complications ; Prosthesis Implantation/methods ; Aged ; Subclavian Vein/surgery ; Subclavian Vein/diagnostic imaging
مستخلص: Central venous obstruction in the cardiac implantable electronic devices (CIED) population is commonly due to thrombosis and fibrosis secondary to the passage of pre-existing leads. However, vein occlusion before CIED implantation is uncommon, and one cause is retrosternal goiters. We report a case where the failure of the initial implantation of a primary CIED led to an unusual implantation route without goiter excision. The patient had an indication for cardiac resynchronization therapy (CRT) given his left ventricular (LV) function was impaired and had second-degree heart block Mobitz Type II; however, he had occluded bilateral subclavian veins due to a sizeable retrosternal goiter. This obstruction led to the implantation of a single lead pacemaker via the right femoral vein after multiple failed attempts at CRT, dual chamber pacemaker and left bundle branch area pacing (LBBaP).
(© 2023 Wiley Periodicals LLC.)
References: Curtis AB, Worley SJ, Adamson PB, et al. Biventricular pacing for atrioventricular block and systolic dysfunction. N Engl J Med. 2013;368:1585‐1593. doi:10.1056/NEJMoa1210356.
Sandasecra S, Yahya MM, Mamat AZ, Soh JY, Ramely R, Aziz M. A monster in the chest: a tale of a goitre. Cureus. 2022;14:e25827. doi:10.7759/cureus.25827.
Nakayama H, Goda M, Kohagura K, et al. A large substernal goitre that extended to both sides of the thorax. Case Rep Surg. 2018. doi:10.1155/2018/6107982. Article ID 6107982.
Rios A, Rodriguez JM, Canteras M, et al. Surgical management of multinodular goiter with compression symptoms. Arch Surg. 2005;140:49‐53. doi:10.1001/archsurg.140.1.49.
Lickfett L, Bitzen A, Arepally A, et al. Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement. Europace. 2004;6:25‐31. doi:10.1016/j.eupc.2003.09.001.
Antonelli D, Turgeman Y, Kaveh Z, Artoul S, Rosenfeld T. Short‐term thrombosis after transvenous permanent pacemaker insertion. Pacing Clin Electrophysiol. 1989;12:280‐282. doi:10.1111/j.1540‐8159.1989.tb02660.x.
Boullin JP, Skene A, Rozkovec A. Unusual case of initial failure of pacemaker implantation. EP Europace. 2010;12:1651‐1652. doi:10.1093/europace/euq270.
Antonelli D, Freedberg NA, Turgeman Y. Supraclavicular vein approach to overcoming ipsilateral chronic subclavian vein obstruction during pacemaker–ICD lead revision or upgrading. EP Europace. 2010;12:1596‐1599. doi:10.1093/europace/euq314.
Ellestad MH, Caso R, Greenberg PS. Permanent pacemaker implantation using the femoral vein: a preliminary report. Pacing Clin Electrophysiol. 1980;3:418‐423. doi:10.1111/j.1540‐8159.1980.tb05250.x.
Rodrigues P, Reis H, Lagarto V, et al. Permanent pacemaker using a femoral approach. Rev Port Cardiol. 2014;33:733.e1‐733.e6. doi:10.1016/j.repce.2014.05.005.
فهرسة مساهمة: Keywords: cardiac implantable electronic devices; central venous obstruction; femoral vein access; retrosternal goiter
تواريخ الأحداث: Date Created: 20230818 Date Completed: 20240425 Latest Revision: 20240425
رمز التحديث: 20240425
DOI: 10.1111/pace.14806
PMID: 37594289
قاعدة البيانات: MEDLINE
الوصف
تدمد:1540-8159
DOI:10.1111/pace.14806