دورية أكاديمية
The Development of a Thick-Lens Post-Myopic Laser Vision Correction Intraocular Lens Calculation Formula.
العنوان: | The Development of a Thick-Lens Post-Myopic Laser Vision Correction Intraocular Lens Calculation Formula. |
---|---|
المؤلفون: | Debellemanière G; Department of Ophthalmology, Rothschild Foundation Hospital (G.D., N.M., A.S., D.G.), Paris, France., Mechleb N; Department of Ophthalmology, Rothschild Foundation Hospital (G.D., N.M., A.S., D.G.), Paris, France., Bernier T; Clinique Ophtalmologique Lamartine (T.B., J.-M.A.), Paris, France., Ancel JM; Clinique Ophtalmologique Lamartine (T.B., J.-M.A.), Paris, France., Gauvin M; Department of Ophthalmology and Visual Sciences, McGill University (M.G., A.W.), Montreal, Quebec, Canada; LASIK MD (M.G., A.W.), Montreal, Quebec, Canada., Wallerstein A; Department of Ophthalmology and Visual Sciences, McGill University (M.G., A.W.), Montreal, Quebec, Canada; LASIK MD (M.G., A.W.), Montreal, Quebec, Canada., Saad A; Department of Ophthalmology, Rothschild Foundation Hospital (G.D., N.M., A.S., D.G.), Paris, France., Gatinel D; Department of Ophthalmology, Rothschild Foundation Hospital (G.D., N.M., A.S., D.G.), Paris, France. Electronic address: gatinel@gmail.com. |
المصدر: | American journal of ophthalmology [Am J Ophthalmol] 2024 Jun; Vol. 262, pp. 40-47. Date of Electronic Publication: 2023 Oct 19. |
نوع المنشور: | Journal Article |
اللغة: | English |
بيانات الدورية: | Publisher: Elsevier Science Country of Publication: United States NLM ID: 0370500 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1879-1891 (Electronic) Linking ISSN: 00029394 NLM ISO Abbreviation: Am J Ophthalmol Subsets: MEDLINE |
أسماء مطبوعة: | Publication: 1999- : New York, NY : Elsevier Science Original Publication: [Chicago, etc., Ophthalmic Pub. Co., etc.] |
مواضيع طبية MeSH: | Lenses, Intraocular* , Refraction, Ocular*/physiology , Biometry* , Myopia*/surgery , Myopia*/physiopathology , Algorithms* , Visual Acuity*/physiology , Optics and Photonics* , Lens Implantation, Intraocular*, Humans ; Retrospective Studies ; Female ; Male ; Middle Aged ; Adult ; Aged ; Phacoemulsification ; Keratomileusis, Laser In Situ/methods |
مستخلص: | Purpose: To describe the development of the post-myopic laser vision correction (LVC) version of the PEARL-DGS intraocular lens (IOL) calculation formula and to evaluate its outcomes on an independent test set. Design: Retrospective, single-center case series. Methods: A modified lens position prediction algorithm was designed along with methods to predict the posterior corneal curvature radius and correct the corneal power measurement error. A different set of previously operated eyes that underwent LVC was used to evaluate the prediction precision of the post-LVC formula. Results: Post-LVC PEARL-DGS formula significantly reduced mean absolute error of prediction in comparison to Haigis-L, Shammas, and American Society of Cataract and Refractive Surgery (ASCRS) average formulas (P < .001). It exhibited similar postoperative refractive precision as the Barrett True-K No History formula (P = .61). Conclusion: The post-LVC formula development process described in this article performed as well as the state-of-the-art post-LVC formula on the present test set. Further studies are required to assess its efficacy in other independent sets. (Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.) |
تواريخ الأحداث: | Date Created: 20231021 Date Completed: 20240516 Latest Revision: 20240516 |
رمز التحديث: | 20240517 |
DOI: | 10.1016/j.ajo.2023.09.023 |
PMID: | 37865388 |
قاعدة البيانات: | MEDLINE |
تدمد: | 1879-1891 |
---|---|
DOI: | 10.1016/j.ajo.2023.09.023 |