دورية أكاديمية

Instrumentation time and effectiveness of hand and rotary files in a prototyped second mandibular primary molar: A micro-CT study.

التفاصيل البيبلوغرافية
العنوان: Instrumentation time and effectiveness of hand and rotary files in a prototyped second mandibular primary molar: A micro-CT study.
المؤلفون: Rêgo EF; Department of Pediatric Dentistry and Orthodontics, School of Dentistry, Universidade Federal do Rio de Janeiro-UFRJ, Rio de Janeiro, Brazil., Silva RPV; Department of Pediatric Dentistry and Orthodontics, School of Dentistry, Universidade Federal do Rio de Janeiro-UFRJ, Rio de Janeiro, Brazil., de Sá Silva AS; Laboratory for Nuclear Instrumentation, Universidade Federal do Rio de Janeiro-UFRJ, Rio de Janeiro, Brazil., Marceliano-Alves MFV; Department of Endodontics, Faculty of Dentistry, Universidade Iguaçu, Nova Iguaçu, Brazil., Lopes RT; Laboratory for Nuclear Instrumentation, Universidade Federal do Rio de Janeiro-UFRJ, Rio de Janeiro, Brazil., Primo LG; Department of Pediatric Dentistry and Orthodontics, School of Dentistry, Universidade Federal do Rio de Janeiro-UFRJ, Rio de Janeiro, Brazil., Neves AA; Department of Pediatric Dentistry and Orthodontics, School of Dentistry, Universidade Federal do Rio de Janeiro-UFRJ, Rio de Janeiro, Brazil.
المصدر: International journal of paediatric dentistry [Int J Paediatr Dent] 2024 Jul; Vol. 34 (4), pp. 383-393. Date of Electronic Publication: 2023 Nov 23.
نوع المنشور: Journal Article; Comparative Study
اللغة: English
بيانات الدورية: Publisher: Blackwell Scientific Publications Country of Publication: England NLM ID: 9107511 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1365-263X (Electronic) Linking ISSN: 09607439 NLM ISO Abbreviation: Int J Paediatr Dent Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Oxford : Blackwell Scientific Publications, c1991-
مواضيع طبية MeSH: Molar* , Root Canal Preparation*/instrumentation , Tooth, Deciduous* , X-Ray Microtomography* , Mandible*/surgery, Humans ; Equipment Design ; Dental Instruments ; Time Factors ; In Vitro Techniques
مستخلص: Background: Eccentric instruments have been proposed as more effective and less time-consuming for endodontic instrumentation.
Aim: To compare biomechanical outcomes of different instrumentation systems and time undertaken for instrumentation in resin prototypes.
Design: Sixty standardized prototypes of mandibular second primary molars were instrumented according to the following systems: K-files, ProTaper Next (PTN), XP-endo Shaper (XPS), XP-endo Finisher (XPF), XP-Clean (XPC), and Sequence Baby File (SBF; n = 10/each). Irrigation was performed with saline with simultaneous aspiration, and time spent was recorded. The prototypes were micro-CT-scanned before and after the instrumentation, and image sets were reconstructed and registered. Non-instrumented areas, accumulated debris, removed root material volume, and canal transportation were quantified. Data were analyzed through ANOVA, the Kruskal-Wallis test, and the Wilcoxon signed-rank test (α = 5%).
Results: K-files and SBF resulted in more instrumentation time (p < .05). SBF, XPC and PTN removed less root dentine (p < .05), but PTN left more untouched areas (p < .05). Accumulated debris were lower for XPC and SBF (p < .05). Canal transportation was similar among the groups.
Conclusion: Rotary systems reduced instrumentation time, whereas SBF and XPC resulted in more conservative instrumentation, with less debris accumulation and non-instrumented areas. A dedicated paediatric endodontic system (SBF) outperformed eccentric instruments in terms of effectiveness.
(© 2023 BSPD, IAPD and John Wiley & Sons Ltd.)
References: American Academy of Pediatric Dentistry. Pulp Therapy for Primary and Immature Permanent Teeth. The Reference Manual of Pediatric Dentistry. Vol 2021. American Academy of Pediatric Dentistry; 2021:399‐407.
Ahmed HM. Anatomical challenges, electronic working length determination and current developments in root canal preparation of primary molar teeth. Int Endod J. 2013;46:1011‐1022.
Katge F, Wakpanjar MM. Root canal morphology of primary molars by clearing technique: an in vitro study. J Indian Soc Pedod Prev Dent. 2018;36:151‐157.
Hidalgo LR, Silva LA, Leoni GB, et al. Mechanical preparation showed superior shaping ability than manual technique in primary molars: a micro‐computed tomography study. Braz Dent J. 2017;28:453‐460.
George S, Anandarai S, Isaac JS, John SA, Harris A. Rotary endodontics in primary teeth: a review. Saudi Dent J. 2016;28:12‐17.
Pinheiro SL, Araujo G, Bincelli I, Cunha R, Bueno C. Evaluation of cleaning capacity and instrumentation time of manual, hybrid and rotary instrumentation techniques in primary molars. Int Endod J. 2012;45:379‐385.
Silva LA, Leonardo MR, Nelson‐Filho P, Tanomaru JM. Comparison of rotary and manual instrumentation techniques on cleaning capacity and instrumentation time in deciduous molars. J Dent Child. 2004;71:45‐47.
Poly A, Marques F, Moura Sassone L, Karabucak B. The shaping ability of WaveOne Gold, TRUShape and XP‐endo Shaper systems in oval‐shaped distal canals of mandibular molars: a microcomputed tomographic analysis. Int Endod J. 2021;54:2300‐2306.
Poly A, Marques F, Lee J, Setzer FC, Karabucak B. XP‐endo Finisher effectively reduces hard‐tissue debris accumulated in root canals with isthmus after preparation with a reciprocating file system. Aust Endod J. 2023;49(2):279‐286.
Jose J, Teja KV, Silva EJ, Janani K, Siddique R, Rossi‐Fedele G. Centric versus eccentric engine‐driven endodontic instrument design for microbial load reduction‐a systematic review and meta‐analysis of randomised clinical trials. Aust Endod J. 2023;49(suppl 1):515‐527.
Tabassum S, Zafar K, Umer F. Nickel‐titanium rotary file systems: what's new? Eur Endod J. 2019;4:111‐117.
Moraes R, Perez R, Silva A, et al. Micro‐CT evaluation of root canal preparation with rotary instrumentation on prototyped primary incisors. Braz Oral Res. 2021;35:e132.
MK Life. Protocolos de uso: limas MK Life. Available in: https://www.mklife.com.br/limas‐rotatorias/sbf‐sequence‐baby‐files/sequence‐baby‐file‐mklife‐kit‐sortido.html. Accessed in October 2022.
Moraes RD, Santos TM, Marceliano‐Alves MF, et al. Reciprocating instrumentation in a maxillary primary central incisor: a protocol tested in a 3D printed prototype. Int J Paediatr Dent. 2019;29:50‐57.
Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol. 1971;32:271‐275.
Primo LG, Pintor AV, Allegretto MJ, et al. Protocolo de pulpectomia para dentes decíduos: um guia clínico e prático baseado em evidências científicas. Rev Cient CRO‐RJ. 2021;6:38‐46.
Fedorov A, Beichel R, Kalpathy‐Cramer J, et al. 3D Slicer as an image computing platform for the quantitative imaging network. Magn Reson Imaging. 2012;30:1323‐1341.
Schindelin J, Arganda‐Carreras I, Frise E, et al. FIJI: An open source platform for biological image analysis. Nat Methods. 2012;9:676‐682. doi:10.1038/nmeth.2019.
Neves AA, Silva EJ, Roter JM, et al. Exploiting the potential of free software to evaluate root canal biomechanical preparation outcomes through micro‐CT images. Int Endod J. 2015;48:1033‐1042.
Bolte S, Cordelières FP. A guided tour into subcellular colocalization analysis in light microscopy. J Microsc. 2006;224:213‐232.
Xavier SR, de Lima CO, Marceliano‐Alves MF, Lacerda MF, Lopes RT, Campos CN. Shaping ability of two root canal instrumentation systems in oval‐shaped canals: a microcomputed tomography study. Aust Endod J. 2021;47:252‐259.
Cohen J. Statistical Power Analysis for the Behavioral Sciences. 2nd ed. Routledge; 1988:567.
Mello‐Moura A, Bresolin CR, Moura‐Netto C, et al. Use of artificial primary teeth for endodontic laboratory research: experiments related to canal length determination. BMC Oral Health. 2017;17:131.
Priyadarshini P, Jeevanandan G, Govindaraju L, Subramanian E. Clinical evaluation of instrumentation time and quality of obturation using paediatric hand and rotary file systems with conventional hand K‐files for pulpectomy in primary mandibular molars: a double‐blinded randomized controlled trial. Eur Arch Paed Dent. 2020;21:693‐701.
Barasuol JC, Alcalde MP, Bortoluzzi EA, Duarte MA, Cardoso M, Bolan M. Shaping ability of hand, rotary and reciprocating files in primary teeth: a micro‐CT study in vitro. Eur Arch Paediatr Dent. 2021;22:195‐201.
Boonchoo K, Leelataweewud P, Yanpiset K, Jirarattanasopha V. Simplify pulpectomy in primary molars with a single‐file reciprocating system: a randomized controlled clinical trial. Clin Oral Invest. 2020;24:2683‐2689.
Kummer TR, Calvo MC, Cordeiro MM, de Sousa VR, de Carvalho Rocha MJ. Ex‐vivo study of manual and rotary instrumentation techniquesin human primary teeth. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008;105:e84‐e92.
Carvalho KK, Petean IB, Silva‐Sousa AC, et al. Impact of several NiTi‐thermally treated instrumentation systems on biomechanical preparation of curved root canals in extracted mandibular molars. Int Endod J. 2022;55(1):124‐136.
Azar MR, Safi L, Nikaein A. Comparison of the cleaning capacity of mtwo and protaper rotary systems and manual instruments in primary teeth. Dent Res J. 2012;9:146‐151.
Asif A, Jeevanandan G, Govindaraju L, Vignesh R, Subramanian EM. Comparative evaluation of extrusion of apical debris in primary anterior teeth using two different rotary systems and hand files: an in vitro study. Contemp Clin Dent. 2019;10:512‐516.
Kaya E, Elbay M, Yigit D. Evaluation of the self‐adjusting file system (SAF) for the instrumentation of primary molar root canals: a micro‐computed tomographic study. Eur J Paed Dent. 2017;18:105‐110.
Ochoa‐Romero T, Mendez‐Gonzalez V, Flores‐Reyes H, Pozos‐Guillen AJ. Comparison between rotary and manual techniques on duration of instrumentation and obturation times in primary teeth. J Clin Ped Dent. 2011;35:359‐363.
Manker A, Solanki M, Tripathi A, Jain ML. Biomechanical preparation in primary molars using manual and three NiTi instruments: a cone‐beam‐computed tomographic in vitro study. Eur Arch Paediatr Dent. 2020;21:203‐213.
Shaikh SM, Goswami M. Evaluation of the effect of different root canal preparation techniques in primary teeth using CBCT. J Clin Pediatr Dent. 2018;42:250‐255.
Selvakumar H, Kavitha S, Thomas E, Anadhan V, Vijayakumar R. Computed tomographic evaluation of K3 rotary and stainless steel K file instrumentation in primary teeth. JDR Clin Transl Res. 2016;10:ZC05‐ZC08.
Garcia Filho PF, Letra A, Menezes R, Carmo AM. Danger zone in mandibular molars before instrumentation: an in vitro study. J Appl Oral Sci. 2003;11:324‐326.
Ozcan G, Sekerci AE, Cantekin K, Aydinbelge M, Dogan S. Evaluation of root canal morphology of human primary molars by using CBCT and comprehensive review of the literature. Acta Odontol Scand. 2016;74:250‐258.
Gavini G, Santos MD, Caldeira CL, et al. Nickel‐titanium instruments in endodontics: a concise review of the state of the art. Braz Oral Res. 2018;32:e67.
Yüksel BN, Öncü A, Çelİkten B, Bİlecenoğlu B, Orhan AI, Orhan K. Micro‐CT evaluation of ‘danger zone’ and microcrack formation in mesial root canals of primary teeth with single‐file rotary and reciprocating systems. Int J Paediatr Dent. 2022;32:109‐115.
Angker L, Swain MV, Kilpatrick N. Micro‐mechanical characterization of the properties of primary tooth dentine. J Dent. 2003;31:261‐267.
معلومات مُعتمدة: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior; Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro
فهرسة مساهمة: Keywords: X‐ray microtomography; deciduous; endodontics instrumentation; pulpectomy; tooth
تواريخ الأحداث: Date Created: 20231123 Date Completed: 20240607 Latest Revision: 20240607
رمز التحديث: 20240607
DOI: 10.1111/ipd.13136
PMID: 37994194
قاعدة البيانات: MEDLINE
الوصف
تدمد:1365-263X
DOI:10.1111/ipd.13136