دورية أكاديمية

Establishment of local diagnostic reference levels for abdomen and chest radiographies in the region of Algarve, Portugal.

التفاصيل البيبلوغرافية
العنوان: Establishment of local diagnostic reference levels for abdomen and chest radiographies in the region of Algarve, Portugal.
المؤلفون: Arriaga A; Departamento de Física da Faculdade de Ciências da Universidade de Lisboa, Campo Grande, 1749-016 Lisboa, Portugal. Electronic address: amarriaga@ciencias.ulisboa.pt., Gonçalves C; Departamento de Física da Faculdade de Ciências da Universidade de Lisboa, Campo Grande, 1749-016 Lisboa, Portugal; Centro Oncológico Dra Natalia Chaves, Joaquim Chaves Saúde, Rua Manuel Anastácio Alves, 2 2795-533 Carnaxide, Portugal., Teles P; Departamento de Física e Astronomia da Faculdade de Ciências da Universidade do Porto, Rua do Campo Alegre, s/n, 4169-007 Porto, Portugal; Centro de Investigação do IPO-PORTO, Rua Dr. António Bernardino de Almeida, 4200-072 Porto, Portugal., Santos J; Instituto Politécnico de Coimbra, ESTESC - Coimbra Health School, Medical Imaging and Radiotherapy, Rua 5 de Outubro, S. Martinho do Bispo, 3046-854 Coimbra, Portugal., Simãozinho P; Administração Regional de Saúde, Algarve, Largo de São Pedro,15, 8000-145 Faro, Portugal., Sousa P; GyRad, Lda, University of Algarve, Gambelas campus, Pav. H5, 8005-139 Faro, Portugal.
المصدر: European journal of radiology [Eur J Radiol] 2024 Jan; Vol. 170, pp. 111248. Date of Electronic Publication: 2023 Dec 05.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Elsevier Science Ireland Ltd Country of Publication: Ireland NLM ID: 8106411 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1872-7727 (Electronic) Linking ISSN: 0720048X NLM ISO Abbreviation: Eur J Radiol Subsets: MEDLINE
أسماء مطبوعة: Publication: Limerick : Elsevier Science Ireland Ltd
Original Publication: Stuttgart ; New York : Thieme, [c1981-
مواضيع طبية MeSH: Diagnostic Reference Levels* , Abdomen*/diagnostic imaging, Adult ; Humans ; Portugal/epidemiology ; Radiation Dosage ; Radiography ; Reference Values
مستخلص: Purpose: To assess doses variabilities in the same abdomen and chest RX exams for adults, to check the need for dose harmonization. To calculate Diagnostic Reference Levels (DRL), mandatory in the European Union, for the Algarve district in Portugal. Our results can be a valuable reference for the Portuguese official determination of DRLs, still in progress.
Method: We considered 4,936 abdomen and 41,320 chest radiographs of adults, covering 7 health centres and 35 radiographers in Algarve. Entrance skin dose (ESD) was calculated for each radiograph and the corresponding uncertainty estimated. Mean doses per centre and per technician, and their uncertainties, were calculated to access dose variabilities. DRLs, set at the 3rd quartile of the total ESD distribution, were determined for a standard patient and for intervals of body mass index (BMI) to study their correlation with patient anatomical variations. Standard quartile errors were estimated.
Results: Our results suggest significant dispersion in applied ESDs among different centres and radiographers. Estimates of DRLs also show small fluctuations across years and an important dependence on BMI intervals. For a standard patient, they are 8.7 ± 0.1 (abdomen) and 0.44 ± 0.01 (chest), while the European DRLs are, respectively, 5.1 and 0.2 (all in mGy).
Conclusions: Results suggest that there is room for dose optimization and harmonization with European DRLs, urging a national dose survey and the establishment of official national DRLs. Official DRLs in intervals of BMI would be quite beneficial, to avoid unnecessary dose exposures.
Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(Copyright © 2023 Elsevier B.V. All rights reserved.)
فهرسة مساهمة: Keywords: Abdomen and chest radiographs; Body mass index; Diagnostic reference levels; Entrance skin dose; Radiological protection; Standard patient
تواريخ الأحداث: Date Created: 20231216 Date Completed: 20240116 Latest Revision: 20240116
رمز التحديث: 20240116
DOI: 10.1016/j.ejrad.2023.111248
PMID: 38103493
قاعدة البيانات: MEDLINE
الوصف
تدمد:1872-7727
DOI:10.1016/j.ejrad.2023.111248