Native myocardial T1 mapping: influence of spatial resolution on quantitative results and reproducibility.

التفاصيل البيبلوغرافية
العنوان: Native myocardial T1 mapping: influence of spatial resolution on quantitative results and reproducibility.
المؤلفون: Dalmer A; Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany., Meinel FG; Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany., Böttcher B; Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany., Manzke M; Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany., Lorbeer R; Department of Radiology, Ludwig-Maximilian University, Munich, Germany., Weber MA; Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany., Baeßler B; Institute of Diagnostic and Interventional Radiology, University Hospital Wuerzburg, Wuerzburg, Germany., Klemenz AC; Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany.
المصدر: Quantitative imaging in medicine and surgery [Quant Imaging Med Surg] 2024 Jan 03; Vol. 14 (1), pp. 20-30. Date of Electronic Publication: 2023 Nov 14.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: AME Pub Country of Publication: China NLM ID: 101577942 Publication Model: Print-Electronic Cited Medium: Print ISSN: 2223-4292 (Print) Linking ISSN: 22234306 NLM ISO Abbreviation: Quant Imaging Med Surg Subsets: PubMed not MEDLINE
أسماء مطبوعة: Original Publication: [Hong Kong] : AME Pub.
مستخلص: Background: Myocardial mapping techniques can be used to quantitatively assess alterations in myocardial tissue properties. This study aims to evaluate the influence of spatial resolution on quantitative results and reproducibility of native myocardial T1 mapping in cardiac magnetic resonance imaging (MRI).
Methods: In this cross-sectional study with prospective data collection between October 2019 and February 2020, 50 healthy adults underwent two identical cardiac MRI examinations in the radiology department on the same day. T1 mapping was performed using a MOLLI 5(3)3 sequence with higher (1.4 mm × 1.4 mm) and lower (1.9 mm × 1.9 mm) in-plane spatial resolution. Global quantitative results of T1 mapping were compared between high-resolution and low-resolution acquisitions using paired t -test. Intra-class correlation coefficient (ICC) and Bland-Altman statistics (absolute and percentage differences as means ± SD) were used for assessing test-retest reproducibility.
Results: There was no significant difference between global quantitative results acquired with high vs. low-resolution T1 mapping. The reproducibility of global T1 values was good for high-resolution (ICC: 0.88) and excellent for low-resolution T1 mapping (ICC: 0.95, P=0.003). In subgroup analyses, inferior test-retest reproducibility was observed for high spatial resolution in women compared to low spatial resolution (ICC: 0.71 vs. 0.91, P=0.001) and heart rates >77 bpm (ICC: 0.53 vs. 0.88, P=0.004). Apical segments had higher T1 values and variability compared to other segments. Regional T1 values for basal (ICC: 0.81 vs. 0.89, P=0.023) and apical slices (ICC: 0.86 vs. 0.92, P=0.024) showed significantly higher reproducibility in low-resolution compared to high-resolution acquisitions but without differences for midventricular slice (ICC: 0.91 vs. 0.92, P=0.402).
Conclusions: Based on our data, we recommend a spatial resolution on the order of 1.9 mm × 1.9 mm for native myocardial T1 mapping using a MOLLI 5(3)3 sequence at 1.5 T particularly in individuals with higher heart rates and women.
Competing Interests: Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at https://qims.amegroups.com/article/view/10.21037/qims-23-943/coif). F.G.M. received a research grant from GE HealthCare and speaker honoraria from GE HealthCare, Circle Cardiovascular Imaging and Bayer Vital. The other authors have no conflicts of interest to declare.
(2024 Quantitative Imaging in Medicine and Surgery. All rights reserved.)
References: J Cardiovasc Magn Reson. 2017 Oct 9;19(1):75. (PMID: 28992817)
J Cardiovasc Magn Reson. 2013 Oct 14;15:92. (PMID: 24124732)
J Cardiovasc Magn Reson. 2017 Sep 21;19(1):72. (PMID: 28934962)
Radiology. 2006 Mar;238(3):1004-12. (PMID: 16424239)
J Magn Reson Imaging. 2021 Dec;54(6):1763-1772. (PMID: 34075646)
Circulation. 2002 Jan 29;105(4):539-42. (PMID: 11815441)
Cardiovasc Diagn Ther. 2014 Apr;4(2):126-37. (PMID: 24834410)
J Cardiovasc Magn Reson. 2013 Jan 20;15:13. (PMID: 23331520)
J Am Coll Cardiol. 2011 Feb 22;57(8):891-903. (PMID: 21329834)
J Cardiovasc Magn Reson. 2013 Jun 18;15:53. (PMID: 23777327)
J Cardiovasc Magn Reson. 2012 Feb 06;14:15. (PMID: 22309452)
Sci Rep. 2022 Nov 4;12(1):18705. (PMID: 36333385)
J Chiropr Med. 2016 Jun;15(2):155-63. (PMID: 27330520)
Nurs Stand. 1991 Mar 20-26;5(26):35-8. (PMID: 1903274)
Korean J Radiol. 2017 Jan-Feb;18(1):113-131. (PMID: 28096723)
J Cardiovasc Magn Reson. 2012 Jun 21;14:42. (PMID: 22720998)
Magn Reson Med. 2007 Jul;58(1):34-40. (PMID: 17659622)
J Cardiovasc Magn Reson. 2014 Jan 04;16:2. (PMID: 24387626)
Int Heart J. 2016 Jul 27;57(4):400-7. (PMID: 27396560)
JACC Cardiovasc Imaging. 2016 Jan;9(1):67-81. (PMID: 26762877)
Open Heart. 2020 Sep;7(2):. (PMID: 32978265)
Wien Klin Wochenschr. 2019 Apr;131(7-8):143-155. (PMID: 30519737)
فهرسة مساهمة: Keywords: Cardiac magnetic resonance imaging; T1; mapping; reproducibility; spatial resolution
تواريخ الأحداث: Date Created: 20240115 Latest Revision: 20240116
رمز التحديث: 20240116
مُعرف محوري في PubMed: PMC10784086
DOI: 10.21037/qims-23-943
PMID: 38223095
قاعدة البيانات: MEDLINE
الوصف
تدمد:2223-4292
DOI:10.21037/qims-23-943