دورية أكاديمية

Enhancing Inverted Internal Limiting Membrane Flap Stability in Macular Hole Retinal Detachment by the "Viscoelastic Agent Pool" Technique.

التفاصيل البيبلوغرافية
العنوان: Enhancing Inverted Internal Limiting Membrane Flap Stability in Macular Hole Retinal Detachment by the "Viscoelastic Agent Pool" Technique.
المؤلفون: Fan Y; National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China., Chen L, Wu M, Lin L, Li H, Zheng B
المصدر: Retina (Philadelphia, Pa.) [Retina] 2024 Jun 01; Vol. 44 (6), pp. 1100-1106.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Lippincott Williams & Wilkins Country of Publication: United States NLM ID: 8309919 Publication Model: Print Cited Medium: Internet ISSN: 1539-2864 (Electronic) Linking ISSN: 0275004X NLM ISO Abbreviation: Retina Subsets: MEDLINE
أسماء مطبوعة: Publication: Hagerstown, MD : Lippincott Williams & Wilkins
Original Publication: Philadelphia : Lippincott, [1981?-
مواضيع طبية MeSH: Retinal Perforations*/surgery , Retinal Perforations*/physiopathology , Retinal Detachment*/surgery , Retinal Detachment*/physiopathology , Visual Acuity*/physiology , Vitrectomy*/methods , Surgical Flaps* , Basement Membrane*/surgery , Tomography, Optical Coherence* , Endotamponade*/methods, Humans ; Middle Aged ; Aged ; Female ; Male ; Aged, 80 and over ; Retrospective Studies ; Follow-Up Studies
مستخلص: Purpose: To evaluate the surgical, anatomical, and functional results of "viscoelastic agent pool" technique-assisted stability of inverted internal limiting membrane flap in macular hole retinal detachment.
Methods: The innovative surgical technique was performed on 10 patients with macular hole retinal detachment. The primary outcomes included best-corrected visual acuity after surgery, rate of closure of macular hole, retinal reattachment, and occurrence of complications.
Results: The mean age of the individuals was 67.70 ± 8.75 (range, 55-84) years; mean axial length, 29.34 ± 1.53 (range, 27.10-30.93) mm; mean corrected MH diameter, 685.30± 345.65 (range, 172-1,325) µ m; and average follow-up period, 6.01 ± 1.71 (range, 3.10-8.4) months. In 6 eyes (60%), the postoperative best-corrected visual acuity showed improvement. All patients had macular hole closure, and the retinal reattachment rate was 100%. No postoperative complications were noted.
Conclusion: The "viscoelastic agent pool" technique, an innovative surgical approach designed to enhance the stability of the internal limiting membrane flap, serves as an effective adjunctive procedure for the inverted internal limiting membrane flap technique. It presents a viable option for patients with macular hole retinal detachment.
(Copyright © 2024 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the Opthalmic Communications Society, Inc.)
References: Gao X, Guo J, Meng X, et al. A meta-analysis of vitrectomy with or without internal limiting membrane peeling for macular hole retinal detachment in the highly myopic eyes. BMC Ophthalmol 2016;16:87.
Michalewska Z, Michalewski J, Adelman RA, Nawrocki J. Inverted internal limiting membrane flap technique for large macular holes. Ophthalmology 2010;117:2018–2025.
Chatziralli I, Machairoudia G, Kazantzis D, et al. Inverted internal limiting membrane flap technique for myopic macular hole: a meta-analysis. Surv Ophthalmol 2021;66:771–780.
Lim LS, Tsai A, Wong D, et al. Prognostic factor analysis of vitrectomy for retinal detachment associated with myopic macular holes. Ophthalmology 2014;121:305–310.
Huang D, Chopra V, Lu ATH, et al. Does optic nerve head size variation affect circumpapillary retinal nerve fiber layer thickness measurement by optical coherence tomography? Invest Ophthalmol Vis Sci 2012;53:4990–4997.
Kang SW, Ahn K, Ham DI. Types of macular hole closure and their clinical implications. The Br J Ophthalmol 2003;87:1015–1019.
Wu AL, Ling KP, Lai CC. Management of macular hole retinal detachment. In: Chang A, Mieler WF, Ohji M, eds. Macular Surgery. Singapore: Springer; 2020:271–281.
Kaiser PK. Prospective evaluation of visual acuity assessment: a comparison of snellen versus ETDRS charts in clinical practice (an AOS Thesis). Trans Am Ophthalmol Soc 2009;107:311–324.
Lai CC, Wu AL, Chou HD, et al. Sub-perfluoro-n-octane injection of ocular viscoelastic device assisted inverted internal limiting membrane flap for macular hole retinal detachment surgery: a novel technique. BMC Ophthalmol 2020;20:116.
Yang JM, Kim JG. Internal limiting membrane handling in macular hole surgery: the infusion direction manipulation and infusion off techniques. Eur Rev Med Pharmacol Sci 2022;26:2395–2398.
Wang X, Zhu Y, Xu H. Inverted multi-layer internal limiting membrane flap for macular hole retinal detachment in high myopia. Sci Rep 2022;12:10593.
Finn AP, Mahmoud TH. Internal limiting membrane retracting door for myopic macular holes. Retina 2019;39:S92–S94.
Borkenstein AF, Borkenstein EM, Malyugin B. Ophthalmic viscosurgical devices (OVDs) in challenging cases: a review. Ophthalmol Ther 2021;10:831–843.
Grewal DS, Mahmoud TH. Autologous neurosensory retinal free flap for closure of refractory myopic macular holes. JAMA Ophthalmol 2016;134:229–230.
Lai CC, Chen YP, Wang NK, et al. Vitrectomy with internal limiting membrane repositioning and autologous blood for macular hole retinal detachment in highly myopic eyes. Ophthalmology 2015;122:1889–1898.
Scoles D, Mahmoud TH. Inaccurate measurements confound the study of myopic macular hole. Ophthalmol Retina 2022;6:95–96.
Kim SH, Kim HK, Yang JY, et al. Visual recovery after macular hole surgery and related prognostic factors. Korean J Ophthalmol 2018;32:140–146.
Lorenzi U, Mehech J, Caporossi T, et al. A retrospective, multicenter study on the management of macular holes without residual internal limiting membrane: the refractory macular hole (ReMaHo) study. Graefes Arch Clin Exp Ophthalmol 2022;260:3837–3845.
تواريخ الأحداث: Date Created: 20240117 Date Completed: 20240520 Latest Revision: 20240520
رمز التحديث: 20240520
DOI: 10.1097/IAE.0000000000004035
PMID: 38232294
قاعدة البيانات: MEDLINE
الوصف
تدمد:1539-2864
DOI:10.1097/IAE.0000000000004035