دورية أكاديمية

Simultaneous determination of meloxicam and bupivacaine via a novel modified dual wavelength method and an advanced chemometric approach.

التفاصيل البيبلوغرافية
العنوان: Simultaneous determination of meloxicam and bupivacaine via a novel modified dual wavelength method and an advanced chemometric approach.
المؤلفون: El-Malla SF; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt., Hamza AA; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt., Elagamy SH; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt. samar.elagamy@pharm.tanta.edu.eg.
المصدر: Scientific reports [Sci Rep] 2024 Jan 22; Vol. 14 (1), pp. 1893. Date of Electronic Publication: 2024 Jan 22.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Nature Publishing Group Country of Publication: England NLM ID: 101563288 Publication Model: Electronic Cited Medium: Internet ISSN: 2045-2322 (Electronic) Linking ISSN: 20452322 NLM ISO Abbreviation: Sci Rep Subsets: MEDLINE
أسماء مطبوعة: Original Publication: London : Nature Publishing Group, copyright 2011-
مواضيع طبية MeSH: Chemometrics* , Bupivacaine*, Meloxicam ; Chromatography, High Pressure Liquid ; Spectrophotometry
مستخلص: This study presents two spectrophotometric methods; a novel dual wavelength-derivative spectrophotometry and multivariate curve resolution-alternating least squares (MCR-ALS) for the simultaneous determination of a fixed dose combination of bupivacaine (BUP) and meloxicam (MEL) in a ratio of 30:1. The extended UV spectrum of MEL enables its direct determination at λ max 360 nm with no interference from BUP. The determination of BUP was unfeasible directly because the UV spectra of both drugs are moderately overlapped over the wavelength range of 250-450 nm, thus new chemometric based spectrophotometric methods should be developed for its determination. Dual wavelength-derivative method was employed based on using first derivative spectra. The selected dual wavelengths for determination BUP were 274.6 nm and 374.6 nm where the dA/dλ amplitudes differences for MET are equal to zero. MCR-ALS is advanced chemometric tool that enables analysis of multicomponent samples in complex matrices with high resolution based on the decomposition of signal/spectral data into the pure spectra and corresponding concentration profile. The figures of merits for MCR model show that there is a good agreement between the actual and predicted concentrations for MEL and BUP. The methods were validated and statistically compared with a reported HPLC method.
(© 2024. The Author(s).)
References: Acta Pharm. 2019 Jun 1;69(2):217-231. (PMID: 31259724)
J Anal Methods Chem. 2020 Feb 11;2020:1684172. (PMID: 32104607)
Chem Cent J. 2017 May 25;11(1):43. (PMID: 29086829)
RSC Adv. 2021 Jan 14;11(5):2935-2946. (PMID: 35424235)
J Anal Methods Chem. 2020 May 29;2020:8873003. (PMID: 32566359)
Talanta. 2008 Feb 15;74(5):1201-10. (PMID: 18371770)
J AOAC Int. 2023 Jul 17;106(4):1056-1069. (PMID: 36847431)
Expert Opin Pharmacother. 2002 Oct;3(10):1501-12. (PMID: 12387696)
FASEB J. 2014 Mar;28(3):1317-30. (PMID: 24327606)
Talanta. 2018 May 1;181:204-209. (PMID: 29426502)
Drugs. 2021 Jul;81(10):1203-1211. (PMID: 34228280)
J Neurosci. 2015 Jan 14;35(2):831-42. (PMID: 25589775)
J Drug Target. 2010 Nov;18(9):688-99. (PMID: 20196632)
المشرفين على المادة: VG2QF83CGL (Meloxicam)
Y8335394RO (Bupivacaine)
تواريخ الأحداث: Date Created: 20240122 Date Completed: 20240124 Latest Revision: 20240125
رمز التحديث: 20240125
مُعرف محوري في PubMed: PMC10803767
DOI: 10.1038/s41598-024-51885-z
PMID: 38253707
قاعدة البيانات: MEDLINE
الوصف
تدمد:2045-2322
DOI:10.1038/s41598-024-51885-z