دورية أكاديمية

Comparison of depth of electrode insertion between cochleostomy and round window approach: a cadaveric study.

التفاصيل البيبلوغرافية
العنوان: Comparison of depth of electrode insertion between cochleostomy and round window approach: a cadaveric study.
المؤلفون: Jangra A; Department of Otorhinolaryngology, All India Institute of Medical Sciences, Jodhpur, India., Das KN; Department of Otorhinolaryngology, All India Institute of Medical Sciences, Jodhpur, India., Sharma V; Department of Otorhinolaryngology, All India Institute of Medical Sciences, Jodhpur, India., Timmaraju S; Education and Training, MED-EL India Pvt Ltd, New Delhi, India., Khera P; Department of Diagnostic and Interventional, Radiology, All India Institute of Medical Sciences, Jodhpur, India., Tiwari S; Department of Diagnostic and Interventional, Radiology, All India Institute of Medical Sciences, Jodhpur, India., Soni K; Department of Otorhinolaryngology, All India Institute of Medical Sciences, Jodhpur, India., Choudhury B; Department of Otorhinolaryngology, All India Institute of Medical Sciences, Jodhpur, India., Ghatak S; Department of Anatomy, All India Institute of Medical Sciences, Jodhpur, India., Dixit SG; Department of Anatomy, All India Institute of Medical Sciences, Jodhpur, India., Nayyar AK; Department of Anatomy, All India Institute of Medical Sciences, Jodhpur, India., Goyal A; Department of Otorhinolaryngology, All India Institute of Medical Sciences, Jodhpur, India. meetugoyal@yahoo.com.
المصدر: European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery [Eur Arch Otorhinolaryngol] 2024 Jul; Vol. 281 (7), pp. 3547-3555. Date of Electronic Publication: 2024 Jan 31.
نوع المنشور: Journal Article; Comparative Study
اللغة: English
بيانات الدورية: Publisher: Springer International Country of Publication: Germany NLM ID: 9002937 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1434-4726 (Electronic) Linking ISSN: 09374477 NLM ISO Abbreviation: Eur Arch Otorhinolaryngol Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Heidelberg : Springer International, c1990-
مواضيع طبية MeSH: Round Window, Ear*/surgery , Cochlear Implantation*/methods , Cadaver* , Temporal Bone*/surgery , Temporal Bone*/diagnostic imaging , Cochlea*/surgery , Cochlea*/diagnostic imaging , Cochlear Implants*, Humans ; Cross-Sectional Studies ; Tomography, X-Ray Computed ; Electrodes, Implanted
مستخلص: Introduction: Round window approach and cochleostomy approach can have different depth of electrode insertion during cochlear implantation which itself can alter the audiological outcomes in cochlear implant.
Objective: The current study was conducted to determine the difference in the depth of electrode insertion via cochleostomy and round widow approach when done serially in same temporal bone.
Methodology: This is a cross-sectional study conducted in the Department of Otorhinolaryngology in conjunction with Department of Anatomy and Department of Diagnostic and Interventional Radiology over a period of 1 year. 12-electrode array insertion was performed via either approach (cochleostomy or round window) in the cadaveric temporal bone. HRCT temporal bone scan of the implanted temporal bone was done and depth of insertion and various cochlear parameters were calculated.
Result: A total of 12 temporal bones were included for imaging analysis. The mean cochlear duct length was 32.892 mm; the alpha and beta angles were 58.175° and 8.350°, respectively. The mean angular depth of electrode insertion via round window was found to be 325.2° (SD = 150.5842) and via cochleostomy 327.350 (SD = 112.79) degree and the mean linear depth of electrode insertion via round window was found to be 18.80 (SD = 4.4962) mm via cochleostomy 19.650 (SD = 3.8087) mm, which was calculated using OTOPLAN 1.5.0 software. There was a statically significant difference in linear depth of insertion between round window and cochleostomy. Although the angular depth of insertion was higher in CS group, there was no statistically significant difference with round window type of insertion.
Conclusion: The depth of electrode insertion is one of the parameters that influences the hearing outcome. Linear depth of electrode insertion was found to be more in case of cochleostomy compared to round window approach (p = 0.075) and difference in case of angular depth of electrode insertion existed but not significant (p = 0.529).
(© 2024. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.)
References: Adunka O, Kiefer J, Unkelbach MH, Lehnert T, Gstoettner W (2004) Development and evaluation of an improved cochlear implant electrode design for electric acoustic stimulation. Laryngoscope 114(7):1237–1241. (PMID: 10.1097/00005537-200407000-0001815235353)
Kim BG (2013) Correlation of cochlear nerve size and auditory performance after cochlear implantation in postlingually deaf patients cochlear nerve size and auditory performance. JAMA Otolaryngol Neck Surg 139(6):604. (PMID: 10.1001/jamaoto.2013.3195)
Kuthubutheen J, Grewal A, Symons S, Nedzelski J, Shipp D, Lin V et al (2019) The effect of cochlear size on cochlear implantation outcomes. BioMed Res Int 2019:5849871. (PMID: 10.1155/2019/5849871312759786582906)
Grover M, Sharma S, Singh SN, Kataria T, Lakhawat RS, Sharma MP (2018) Measuring cochlear duct length in Asian population: worth giving a thought! Eur Arch Oto-Rhino-Laryngol Off J Eur Fed Oto-Rhino-Laryngol Soc EUFOS Affil Ger Soc Oto-Rhino-Laryngol Head Neck Surg 275(3):725–728.
Naples JG, Ruckenstein MJ (2020) Cochlear implant. Otolaryngol Clin North Am 53(1):87–102. (PMID: 10.1016/j.otc.2019.09.00431677740)
Schurzig D, Timm ME, Batsoulis C, Salcher R, Sieber D, Jolly C et al (2018) A novel method for clinical cochlear duct length estimation toward patient-specific cochlear implant selection. OTO Open 2(4):2473974X18800238. (PMID: 10.1177/2473974X18800238307195056348517)
Neves CA, Tran ED, Cooperman SP, Blevins NH (2022) Fully automated measurement of cochlear duct length from clinical temporal bone computed tomography. Laryngoscope 132(2):449–458. (PMID: 10.1002/lary.2986934536238)
Jiam NT, Jiradejvong P, Pearl MS, Limb CJ (2016) The effect of round window vs cochleostomy surgical approaches on cochlear implant electrode position: a flat-panel computed tomography study. JAMA Otolaryngol Head Neck Surg 142(9):873–880. (PMID: 10.1001/jamaoto.2016.151227355198)
Jain R, Tiwari P, Kumar S, Mishra P, Pearly PK, Keshri A (2019) A clinico-radiological study: Veria technique of cochlear implant—a study of 50 cases. Indian J Otolaryngol Head Neck Surg Off Publ Assoc Otolaryngol India 71(Suppl 2):1553–1561. (PMID: 10.1007/s12070-019-01633-x)
Woolley AL, Oser AB, Lusk RP, Bahadori RS (1997) Preoperative temporal bone computed tomography scan and its use in evaluating the pediatric cochlear implant candidate. Laryngoscope 107(8):1100–1106. (PMID: 10.1097/00005537-199708000-000179261015)
Gallant S, Friedmann DR, Hagiwara M, Roland JT, Svirsky MA, Jethanamest D (2019) Comparison of skull radiograph and computed tomography measurements of cochlear implant insertion angles. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 40(3):e298-303. (PMID: 10.1097/MAO.0000000000002121)
Seidman DA, Chute PM, Parisier S (1994) Temporal bone imaging for cochlear implantation. Laryngoscope 104(5 Pt 1):562–565. (PMID: 10.1002/lary.55410405108189987)
OTOPLAN-based study of intracochlear electrode position through cochleostomy and round window in transcanal Veria technique. SpringerLink [Internet]. [cited 2023 Apr 29]. Available from: https://link.springer.com/article/ https://doi.org/10.1007/s12070-022-03228-5.
Mistrík P, Jolly C (2016) Optimal electrode length to match patient specific cochlear anatomy. Eur Ann Otorhinolaryngol Head Neck Dis 133(Suppl 1):S68-71. (PMID: 10.1016/j.anorl.2016.05.00127246743)
Alexiades G, Dhanasingh A, Jolly C (2015) Method to estimate the complete and two-turn cochlear duct length. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 36(5):904–907. (PMID: 10.1097/MAO.0000000000000620)
Mertens G, Van Rompaey V, Van de Heyning P, Gorris E, Topsakal V (2020) Prediction of the cochlear implant electrode insertion depth: clinical applicability of two analytical cochlear models. Sci Rep 10(1):3340. (PMID: 10.1038/s41598-020-58648-6320943727039896)
Zahara D, Dewi RD, Aboet A, Putranto FM, Lubis ND, Ashar T (2019) Variations in cochlear size of cochlear implant candidates. Int Arch Otorhinolaryngol 23(2):184–190. (PMID: 10.1055/s-0038-166136030956703)
Svrakic M, Friedmann DR, Berman PM, Davis AJ, Roland JT, Svirsky MA (2015) Measurement of cochlear implant electrode position from intraoperative post-insertion skull radiographs: a validation study. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 36(9):1486–1491. (PMID: 10.1097/MAO.0000000000000852)
Canfarotta MW, Dillon MT, Brown KD, Pillsbury HC, Dedmon MM, O’Connell BP (2022) Insertion depth and cochlear implant speech recognition outcomes: a comparative study of 28- and 31.5-mm lateral wall arrays. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 43(2):183–189. (PMID: 10.1097/MAO.0000000000003416)
O’Connell BP, Hunter JB, Haynes DS, Holder JT, Dedmon MM, Noble JH et al (2017) Insertion depth impacts speech perception and hearing preservation for lateral wall electrodes. Laryngoscope 127(10):2352–2357. (PMID: 10.1002/lary.26467283040965825186)
Salam S, Tayel S, Mehanna A, Eid M, Afifi W (2013) Comparison of scalar location and insertion depth of cochlear implant electrode implanted through the round window versus cochleostomy approach. J Int Adv Otol 1(9):30–37.
Khan AM, Handzel O, Burgess BJ, Damian D, Eddington DK, Nadol JB (2005) Is word recognition correlated with the number of surviving spiral ganglion cells and electrode insertion depth in human subjects with cochlear implants? Laryngoscope 115(4):672–677. (PMID: 10.1097/01.mlg.0000161335.62139.8015805879)
فهرسة مساهمة: Keywords: Cochlear implants; Cochleostomy; Depth of insertion of electrode; Round window insertion
تواريخ الأحداث: Date Created: 20240131 Date Completed: 20240627 Latest Revision: 20240627
رمز التحديث: 20240628
DOI: 10.1007/s00405-024-08466-7
PMID: 38294508
قاعدة البيانات: MEDLINE
الوصف
تدمد:1434-4726
DOI:10.1007/s00405-024-08466-7