A challenge and solution for automatic thin slice thickness measurements on images of the Catphan phantom.

التفاصيل البيبلوغرافية
العنوان: A challenge and solution for automatic thin slice thickness measurements on images of the Catphan phantom.
المؤلفون: Anam C; Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia., Amilia R; Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia., Naufal A; Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia., Sutanto H; Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia., Dougherty G; Department of Applied Physics and Medical Imaging, California State University Channel Islands, Camarillo, CA 93012, United States of America.
المصدر: Biomedical physics & engineering express [Biomed Phys Eng Express] 2024 Feb 23; Vol. 10 (2). Date of Electronic Publication: 2024 Feb 23.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: IOP Publishing Ltd Country of Publication: England NLM ID: 101675002 Publication Model: Electronic Cited Medium: Internet ISSN: 2057-1976 (Electronic) Linking ISSN: 20571976 NLM ISO Abbreviation: Biomed Phys Eng Express Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Bristol : IOP Publishing Ltd., [2015]-
مواضيع طبية MeSH: Tomography, X-Ray Computed*/methods, Phantoms, Imaging
مستخلص: Purpose . The use of the Hough transform for angle detection is quite accurate for relatively wide slice thickness. However, the Hough transform fails to accurately detect the angle for thin slice thickness. This study proposes a method for automatically measuring the thickness of thin slices on images of a Catphan phantom. Methods . In the proposed method, the angle of the phantom's orientation was determined based on the relative coordinates of the four hole objects in the phantom. After the angles of the wires were determined, the profiles of pixel values across the wire objects were constructed. Finally, their full widths at half maximum (FWHMs) were determined and multiplied by tan 23° to obtain the slice thicknesses of the images. The results of the proposed method were compared to a previous method, which used the Hough transform to obtain the phantom's orientation. We used slice thicknesses ranging from 0.8 mm to 5.0 mm, and phantom angles from 0° to 10°. Results . Our proposed method detected the angle of the phantom accurately for thin slices, whereas a previous method did not accurately detect the angle. The results of the slice thickness using this current method were slightly higher (within 7.9%) compared to the previous method. However, the results of the two methods did not differ significantly ( p -value > 0.05). Using different angles, the current method detected all the angles more accurately. Again, the slice thicknesses were not significantly different from the previous method ( p -value > 0.05). Conclusion . The proposed method for measuring the thickness of thin slices in an image of a Catphan phantom, based on the relative coordinates of the four hole objects in the phantom, outperformed a previous method based on the Hough transform.
(© 2024 IOP Publishing Ltd.)
فهرسة مساهمة: Keywords: CT scan; Catphan phantom; image quality; slice thickness