دورية أكاديمية

Simultaneous brain and neck time-of-flight MRA using spiral multiband with localized quadratic encoding.

التفاصيل البيبلوغرافية
العنوان: Simultaneous brain and neck time-of-flight MRA using spiral multiband with localized quadratic encoding.
المؤلفون: Peng X; Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.; Department of Radiology, University of Iowa, Iowa City, Iowa, USA., Wang D; Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA., Borup D; Royal Philips, Rochester, Minnesota, USA., Krishnamoorthy G; Royal Philips, Rochester, Minnesota, USA.; Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA., Pipe JG; Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.; Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.
المصدر: Magnetic resonance in medicine [Magn Reson Med] 2024 Sep; Vol. 92 (3), pp. 1095-1103. Date of Electronic Publication: 2024 Apr 04.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Wiley Country of Publication: United States NLM ID: 8505245 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1522-2594 (Electronic) Linking ISSN: 07403194 NLM ISO Abbreviation: Magn Reson Med Subsets: MEDLINE
أسماء مطبوعة: Publication: 1999- : New York, NY : Wiley
Original Publication: San Diego : Academic Press,
مواضيع طبية MeSH: Magnetic Resonance Angiography*/methods , Neck*/diagnostic imaging , Brain*/diagnostic imaging , Signal-To-Noise Ratio*, Humans ; Algorithms ; Image Processing, Computer-Assisted/methods ; Carotid Arteries/diagnostic imaging ; Adult ; Male
مستخلص: Purpose: To develop a method that achieves simultaneous brain and neck time-of-flight (ToF) magnetic resonance angiography (MRA) within feasible scan timeframes.
Methods: Localized quadratic (LQ) encoding is efficient for both signal-to-noise ratio (SNR) and in-flow enhancement. We proposed a spiral multiband LQ method to enable simultaneous intracranial and carotid ToF-MRA within a single scan. To address the venous signal contamination that becomes a challenge with multiband (MB) ToF, tilt-optimized non-saturated excitation (TONE) and partial-Fourier slice selection (PFSS) were further introduced in the LQ framework to mitigate the venous signal and improve artery contrast. A sequential spiral MB and LQ reconstruction pipeline was employed to obtain the brain-and-neck image volumes.
Results: The proposed MB method was able to achieve simultaneous brain and neck ToF-MRA within a 2:50-min scan. The complementarily boosted SNR-efficiency by MB and LQ acquisitions allows for the increased spatial coverage without increase in scan time or noticeable compromise in SNR. The incorporation of both TONE and PFSS effectively alleviated the venous contamination with improved small vessel sensitivity. Selection of scan parameters such as the LQ factor and flip angle reflected the trade-off among SNR, blood contrast, and venous suppression.
Conclusions: A novel MB spiral LQ approach was proposed to enable fast intracranial and carotid ToF-MRA with minimized venous corruption. The method has shown promise in MRA applications where large spatial coverage is necessary.
(© 2024 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.)
References: Miyazaki M, Lee VS. Nonenhanced MR angiography. Radiology. 2008;248:20‐43.
Hartung MP, Grist TM, Franc¸ois CJ. Magnetic resonance angiography: current status and future directions. J Cardiovasc Magn Reson. 2011;13:11.
Parker DL, Yuan C, Blatter DD. MR angiography by multiple thin slab 3D acquisition. Magn Reson Med. 1991;17:434‐451.
Schulz J, Boyacioğlu R, Norris DG. Multiband multislab 3D time‐of‐flight magnetic resonance angiography for reduced acquisition time and improved sensitivity. Magn Reson Med. 2016;75:1662‐1668.
Wang D, Krishnamoorthy G, Ooi MB, Pipe JG. Spiral inflow MRA with sliding‐slice localized quadratic encoding. Magn Reson Med. 2023;90:1818‐1829.
Greve T, Sollmann N, Hock A, et al. Highly accelerated time‐of‐flight magnetic resonance angiography using spiral imaging improves conspicuity of intracranial arterial branches while reducing scan time. Eur Radiol. 2020;30:855‐865.
Sartoretti T, Sartoretti E, Schwenk Á, et al. Clinical feasibility of ultrafast intracranial vessel imaging with non‐cartesian spiral 3D time‐of‐flight MR angiography at 1.5T: an intraindividual comparison study. PLoS ONE. 2020;15:e0232372.
Greve T, Sollmann N, Hock A, Zimmer C, Kirschke JS. Novel ultrafast spiral head MR angiography compared to standard MR and CT angiography. J Neuroimaging. 2021;31:45‐56.
Atkinson D, Brant‐Zawadzki M, Gillan G, Purdy D, Laub G. Improved MR angiography: magnetization transfer suppression with variable flip angle excitation and increased resolution. Radiology. 1994;190:890‐894.
Pipe JG. Flow effects in localized quadratic, partial Fourier MRA. Magn Reson Med. 1999;41:309‐314.
Pipe JG. Spatial encoding and reconstruction in MRI with quadratic phase profiles. Magn Reson Med. 1995;33:24‐33.
Pipe JG. Analysis of localized quadratic encoding and reconstruction. Magn Reson Med. 1996;36:137‐146.
Sun C, Yang Y, Cai X, et al. Non‐cartesian slice‐GRAPPA and slice‐SPIRiT reconstruction methods for multiband spiral cardiac MRI. Magn Reson Med. 2020;83:1235‐1249.
Pruessmann KP, Weiger M, Börnert P, Boesiger P. Advances in sensitivity encoding with arbitrary k‐space trajectories. Magn Reson Med. 2001;46:638‐651.
Wang D, Zwart NR, Pipe JG. Joint water‐fat separation and deblurring for spiral imaging. Magn Reson Med. 2018;79:3218‐3228.
Noll DC, Nishimura DG, Macovski A. Homodyne detection in magnetic resonance imaging. IEEE Trans Med Imag. 1991;10:154‐163.
معلومات مُعتمدة: Royal Philips
فهرسة مساهمة: Keywords: localized quadratic RF pulses; partial‐Fourier slice selection; spiral multiband; time‐of‐flight MRA
تواريخ الأحداث: Date Created: 20240405 Date Completed: 20240626 Latest Revision: 20240626
رمز التحديث: 20240627
DOI: 10.1002/mrm.30098
PMID: 38576077
قاعدة البيانات: MEDLINE
الوصف
تدمد:1522-2594
DOI:10.1002/mrm.30098