دورية أكاديمية

Infections Associated with Medtronic Duet External Ventricular Drains - Rhode Island Hospital, Providence, Rhode Island, January 2023-January 2024.

التفاصيل البيبلوغرافية
العنوان: Infections Associated with Medtronic Duet External Ventricular Drains - Rhode Island Hospital, Providence, Rhode Island, January 2023-January 2024.
المؤلفون: Gibas KM, Auld D, Parente S, Horoho J, Mermel LA
المصدر: MMWR. Morbidity and mortality weekly report [MMWR Morb Mortal Wkly Rep] 2024 Apr 11; Vol. 73 (14), pp. 312-316. Date of Electronic Publication: 2024 Apr 11.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: U.S. Centers for Disease Control Country of Publication: United States NLM ID: 7802429 Publication Model: Electronic Cited Medium: Internet ISSN: 1545-861X (Electronic) Linking ISSN: 01492195 NLM ISO Abbreviation: MMWR Morb Mortal Wkly Rep Subsets: MEDLINE
أسماء مطبوعة: Publication: Atlanta, GA : U.S. Centers for Disease Control
Original Publication: [Atlanta] U. S. Dept. of Health, Education, and Welfare, Public Health Service, Center for Disease Control.
مواضيع طبية MeSH: Cross Infection*, United States ; Humans ; Rhode Island/epidemiology ; Drainage/adverse effects ; Brain ; Hospitals ; Retrospective Studies
مستخلص: External ventricular drains (EVDs) are medical devices that are inserted into the ventricles of the brain to drain excess fluid, manage intracranial hypertension, monitor intracranial pressure, and administer medications. Unintentional disconnections and breaks or fractures (breaks) of EVDs or associated drainage system components can result in cerebrospinal fluid (CSF) leakage and increased risk for EVD-associated infections. After replacement of Integra Life Sciences EVD systems with Medtronic Duet EVD systems at Rhode Island Hospital in mid-September 2023, a threefold increase was observed in the prevalence of positive CSF cultures, from 2.8 per 1,000 days with an EVD in place (EVD days) during January-September 2023 to 11.4 per 1,000 EVD days during October 2023-January 2024 (rate ratio [RR] = 5.7; 95% CI = 1.5-22.0; p = 0.01) and an eightfold increase in the prevalence of infections, from 0.7 to 6.5 per 1,000 EVD days (RR = 9.8; 95% CI = 1.1-87.3; p = 0.04). An investigation by Rhode Island Hospital Infection Control during December 2023-January 2024 identified frequent reports of disconnections and breaks of the Medtronic Duet EVD system. A search of the Food and Drug Administration Manufacturer and User Facility Device Experience database identified 326 reports nationwide of disconnection and breaks of components of the Duet EVD system, including 175 during 2023. A Medical Product Safety Network report was filed. The Duet EVD product was ultimately recalled in January 2024, citing disconnections of the EVD system and reports of CSF leakage and infection. Given the widespread use of EVD systems by neurosurgery centers and the risk for EVD-associated infections, a strategy for future consideration by hospital infection prevention and control programs might be inclusion of EVD-associated infections in hospital surveillance programs to rapidly identify increases in these events and determine factors related to such infections to prevent additional infections.
Competing Interests: All authors have completed and submitted the International Committee of Medical Journal Editors form for disclosure of potential conflicts of interest. No potential conflicts of interest were disclosed.
References: Br J Neurosurg. 2008 Apr;22(2):213-8. (PMID: 18348016)
Interdiscip Perspect Infect Dis. 2014;2014:708531. (PMID: 25484896)
Surg Neurol Int. 2015 May 25;6(Suppl 6):S271-4. (PMID: 26069848)
Neurol Clin Pract. 2023 Aug;13(4):e200156. (PMID: 37529300)
تواريخ الأحداث: Date Created: 20240411 Date Completed: 20240415 Latest Revision: 20240415
رمز التحديث: 20240415
مُعرف محوري في PubMed: PMC11008792
DOI: 10.15585/mmwr.mm7314a4
PMID: 38602895
قاعدة البيانات: MEDLINE
الوصف
تدمد:1545-861X
DOI:10.15585/mmwr.mm7314a4