دورية أكاديمية

Physical performance tests have excellent reliability in frail and non-frail patients with prostate cancer.

التفاصيل البيبلوغرافية
العنوان: Physical performance tests have excellent reliability in frail and non-frail patients with prostate cancer.
المؤلفون: Feyzioğlu Ö; Department of Physiotherapy and Rehabilitation, Acibadem Mehmet Ali Aydinlar University, Faculty of Health Sciences, Istanbul, Turkey., Dinçer S; Department of Radiation Oncology, Prof. Dr. Cemil Taşcıoğlu City Hospital, Istanbul, Turkey., Özdemir AE; Department of Physiotherapy and Rehabilitation, Gelisim University, Faculty of Health Sciences, Istanbul, Turkey., Öztürk Ö; Department of Physiotherapy and Rehabilitation, Acibadem Mehmet Ali Aydinlar University, Faculty of Health Sciences, Istanbul, Turkey.
المصدر: Disability and rehabilitation [Disabil Rehabil] 2024 Apr 13, pp. 1-8. Date of Electronic Publication: 2024 Apr 13.
Publication Model: Ahead of Print
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Taylor & Francis Country of Publication: England NLM ID: 9207179 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1464-5165 (Electronic) Linking ISSN: 09638288 NLM ISO Abbreviation: Disabil Rehabil Subsets: MEDLINE
أسماء مطبوعة: Publication: 2015- : Abingdon, Oxford : Taylor & Francis
Original Publication: London ; Washington, DC : Taylor & Francis, c1992-
مستخلص: Purpose: Our aim was to investigate the test-retest reliability of the 2-min walk test (2MWT), timed up and go test (TUG), and five times sit-to-stand test (FTSST) in prostate cancer (PC) patients.
Methods: This study was conducted with 73 patients who were classified into two groups as frail and non-frail determined by the Geriatric-8 questionnaire. Patients performed the 2MWT, TUG, and FTSST tests for two times. The test-retest reliability of the 2MWT, TUG, and FTSST was assessed by calculating the intraclass correlation coefficient (ICC). The standard error of measurement (SEM 95 ) and minimal detectable change (MDC 95 ) values were calculated.
Results: All tests showed excellent test-retest reliability for both groups (ICC (2.1) > 0.90). The SEM 95 and MDC 95 values of 2MWT were 3.09, 8.57, and 3.15 m, 8.73 m for frail and non-frail groups. The SEM 95 and MDC 95 values of TUG for the frail group were 0.6 and 1.66 and 0.43 and 1.19 for the non-frail group, respectively. The SEM 95 and MDC 95 values of FTST for the frail group were 0.68 and 1.88 and for the non-frail group 0.86 and 2.38.
Conclusions: The 2MWT, TUG, and FTSST showed excellent reliability in frail and non-frail older adults with PC which can be used to assess physical performance.
فهرسة مساهمة: Keywords: Prostate cancer; frail; functional test; reliability
Local Abstract: [plain-language-summary] The 2-minute walk test (2MWT), Timed up and go test (TUG) and five times sit to stand tests (FTST) are excellent reliable tests for both frail and non-frail prostate cancer patients.The Minimal Detectable Change (MDC95) value of 2MWT, TUG, and FTST provides important information to clinicians about the clinical progression of oncological patientsClinicians can use one of this evidence-based outcome measures to check change of independent mobility performance with prostate cancer patients.
تواريخ الأحداث: Date Created: 20240413 Latest Revision: 20240413
رمز التحديث: 20240413
DOI: 10.1080/09638288.2024.2340703
PMID: 38613370
قاعدة البيانات: MEDLINE
الوصف
تدمد:1464-5165
DOI:10.1080/09638288.2024.2340703