دورية أكاديمية

Comparable Ventilatory Inefficiency at Maximal and Submaximal Performance in COPD vs. CHF subjects: An Innovative Approach.

التفاصيل البيبلوغرافية
العنوان: Comparable Ventilatory Inefficiency at Maximal and Submaximal Performance in COPD vs. CHF subjects: An Innovative Approach.
عنوان ترانسليتريتد: Ineficiência Ventilatória Comparável no Desempenho Máximo e Submáximo em Indivíduos com DPOC e ICC: Uma Abordagem Inovadora.
المؤلفون: de Campos GGO; Universidade Federal de Mato Grosso do Sul (UFMS) - Hospital Maria Aparecida Pedrossian (HUMAP), Laboratório de Fisiopatologia Respiratória (LAFIR), Campo Grande, MS - Brasil., Goelzer LS; Universidade Federal de Mato Grosso do Sul (UFMS) - Hospital Maria Aparecida Pedrossian (HUMAP), Laboratório de Fisiopatologia Respiratória (LAFIR), Campo Grande, MS - Brasil., Augusto TRL; Universidade Federal de Mato Grosso do Sul (UFMS) - Hospital Maria Aparecida Pedrossian (HUMAP), Laboratório de Fisiopatologia Respiratória (LAFIR), Campo Grande, MS - Brasil., Barbosa GW; Universidade Federal de Mato Grosso do Sul (UFMS) - Hospital Maria Aparecida Pedrossian (HUMAP), Laboratório de Fisiopatologia Respiratória (LAFIR), Campo Grande, MS - Brasil., Chiappa GR; Programa de Pós-graduação em Movimento Humano e Reabilitação, Universidade Evangélica de Goiás, Anápolis, GO - Brasil., van Iterson EH; Seção de Cardiologia Preventiva e Reabilitação, Clínica Cleveland, MN - EUA., Muller PT; Universidade Federal de Mato Grosso do Sul (UFMS) - Hospital Maria Aparecida Pedrossian (HUMAP), Laboratório de Fisiopatologia Respiratória (LAFIR), Campo Grande, MS - Brasil.
المصدر: Arquivos brasileiros de cardiologia [Arq Bras Cardiol] 2024 Apr 29; Vol. 121 (4), pp. e20230578. Date of Electronic Publication: 2024 Apr 29 (Print Publication: 2024).
نوع المنشور: Journal Article; Comparative Study
اللغة: Portuguese; English
بيانات الدورية: Publisher: Sociedad Brasileira De Cardiologia Country of Publication: Brazil NLM ID: 0421031 Publication Model: eCollection Cited Medium: Internet ISSN: 1678-4170 (Electronic) Linking ISSN: 0066782X NLM ISO Abbreviation: Arq Bras Cardiol Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Sao Paulo : Sociedad Brasileira De Cardiologia
مواضيع طبية MeSH: Pulmonary Disease, Chronic Obstructive*/physiopathology , Heart Failure*/physiopathology , Exercise Test*/methods , Oxygen Consumption*/physiology, Humans ; Male ; Middle Aged ; Female ; Aged ; Respiratory Function Tests ; Exercise Tolerance/physiology ; Pulmonary Ventilation/physiology ; Reference Values ; Echocardiography ; Chronic Disease ; Carbon Dioxide
مستخلص: Background: Currently, excess ventilation has been grounded under the relationship between minute-ventilation/carbon dioxide output ( V ˙ E - V ˙ CO 2 ). Alternatively, a new approach for ventilatory efficiency ( η E V ˙ ) has been published.
Objective: Our main hypothesis is that comparatively low levels of η E V ˙ between chronic heart failure (CHF) and chronic obstructive pulmonary disease (COPD) are attainable for a similar level of maximum and submaximal aerobic performance, conversely to long-established methods ( V ˙ E - V ˙ CO 2 slope and intercept).
Methods: Both groups performed lung function tests, echocardiography, and cardiopulmonary exercise testing. The significance level adopted in the statistical analysis was 5%. Thus, nineteen COPD and nineteen CHF-eligible subjects completed the study. With the aim of contrasting full values of V ˙ E - V ˙ CO 2 and η V ˙ E for the exercise period (100%), correlations were made with smaller fractions, such as 90% and 75% of the maximum values.
Results: The two groups attained matched characteristics for age (62±6 vs. 59±9 yrs, p>.05), sex (10/9 vs. 14/5, p>0.05), BMI (26±4 vs. 27±3 Kg m2, p>0.05), and peak V ˙ O 2 (72±19 vs. 74±20 %pred, p>0.05), respectively. The V ˙ E - V ˙ CO 2 slope and intercept were significantly different for COPD and CHF (27.2±1.4 vs. 33.1±5.7 and 5.3±1.9 vs. 1.7±3.6, p<0.05 for both), but η V ˙ E average values were similar between-groups (10.2±3.4 vs. 10.9±2.3%, p=0.462). The correlations between 100% of the exercise period with 90% and 75% of it were stronger for η V ˙ E (r>0.850 for both).
Conclusion: The η V ˙ E is a valuable method for comparison between cardiopulmonary diseases, with so far distinct physiopathological mechanisms, including ventilatory constraints in COPD.
References: Eur J Cardiovasc Prev Rehabil. 2009 Aug;16(4):493-8. (PMID: 19483619)
Eur Respir J. 2009 Sep;34(3):605-15. (PMID: 19282347)
Eur Respir Rev. 2016 Sep;25(141):333-47. (PMID: 27581832)
COPD. 2019 Apr;16(2):174-181. (PMID: 31272243)
Eur J Heart Fail. 2018 Jan;20(1):3-15. (PMID: 28925073)
Eur J Prev Cardiol. 2014 Jul;21(7):847-54. (PMID: 23382540)
Eur Respir J. 2015 Feb;45(2):377-87. (PMID: 25359345)
Int J Cardiol. 2019 Jan 1;274:232-236. (PMID: 30201380)
Am J Respir Crit Care Med. 2001 Oct 15;164(8 Pt 1):1481-6. (PMID: 11704600)
Clin Physiol Funct Imaging. 2006 May;26(3):191-6. (PMID: 16640516)
Am Heart J. 1999 Jun;137(6):1050-6. (PMID: 10347330)
Eur J Heart Fail. 2017 Dec;19(12):1686-1689. (PMID: 28990273)
Clin Chest Med. 2019 Jun;40(2):421-438. (PMID: 31078219)
Chron Respir Dis. 2019 Jan-Dec;16:1479973119887965. (PMID: 31711299)
Eur J Heart Fail. 2005 Oct;7(6):1017-22. (PMID: 16227140)
Respir Care. 2014 Jul;59(7):1034-41. (PMID: 24046458)
Eur J Heart Fail. 2017 Dec;19(12):1675-1685. (PMID: 28990307)
Respir Physiol Neurobiol. 2021 Jul;289:103670. (PMID: 33813050)
Chest. 2010 Oct;138(4):950-5. (PMID: 20522572)
J Card Fail. 2007 May;13(4):259-62. (PMID: 17517344)
Pulm Med. 2013;2013:359021. (PMID: 23766901)
Clin Physiol Funct Imaging. 2021 Jan;41(1):103-109. (PMID: 33112466)
J Appl Res Intellect Disabil. 2018 Sep;31(5):897-904. (PMID: 29573317)
J Am Soc Echocardiogr. 2005 Dec;18(12):1440-63. (PMID: 16376782)
Clin Chest Med. 2014 Mar;35(1):51-69. (PMID: 24507837)
Eur Respir J. 2005 Aug;26(2):319-38. (PMID: 16055882)
Heart. 1997 Feb;77(2):138-46. (PMID: 9068397)
Respirology. 2016 Feb;21(2):211-23. (PMID: 26333038)
Braz J Med Biol Res. 1999 Jun;32(6):729-37. (PMID: 10412551)
J Am Coll Cardiol. 1996 Nov 15;28(6):1567-72. (PMID: 8917273)
Eur J Cardiovasc Prev Rehabil. 2003 Aug;10(4):267-72. (PMID: 14555881)
Heart Lung. 2014 Mar-Apr;43(2):146-51. (PMID: 24594250)
Circulation. 1994 May;89(5):2062-9. (PMID: 8181130)
Int J Cardiol. 2015;189:134-40. (PMID: 25889444)
Eur Respir J. 2017 Jan 3;49(1):. (PMID: 28049168)
Am J Respir Crit Care Med. 2015 Jun 15;191(12):1384-94. (PMID: 25826478)
Front Physiol. 2020 Jun 25;11:659. (PMID: 32714201)
Pediatr Pulmonol. 2020 Feb;55(2):280-282. (PMID: 31682324)
Br Heart J. 1991 Apr;65(4):179-83. (PMID: 2029439)
Eur Respir J. 2018 Feb 7;51(2):. (PMID: 29437936)
Respiration. 2009;77(1):3-17. (PMID: 19145106)
J Bras Pneumol. 2007 Jul-Aug;33(4):397-406. (PMID: 17982531)
فهرسة مساهمة: Local Abstract: [Publisher, Portuguese] Atualmente, o excesso de ventilação tem sido fundamentado na relação entre ventilação-minuto/produção de dióxido de carbono ( V ˙ E − V ˙ CO 2 ). Alternativamente, uma nova abordagem para eficiência ventilatória ( η E V ˙ ) tem sido publicada. [Publisher, Portuguese] Nossa hipótese principal é que níveis comparativamente baixos de η E V ˙ entre insuficiência cardíaca crônica (ICC) e doença pulmonar obstrutiva crônica (DPOC) são atingíveis para um nível semelhante de desempenho aeróbico máximo e submáximo, inversamente aos métodos estabelecidos há muito tempo (inclinação V ˙ E − V ˙ CO 2 e intercepto). [Publisher, Portuguese] Ambos os grupos realizaram testes de função pulmonar, ecocardiografia e teste de exercício cardiopulmonar. O nível de significância adotada na análise estatística foi 5%. Assim, dezenove indivíduos elegíveis para DPOC e dezenove indivíduos elegíveis para ICC completaram o estudo. Com o objetivo de contrastar valores completos de V ˙ E − V ˙ CO 2 e η E V ˙ para o período de exercício (100%), correlações foram feitas com frações menores, como 90% e 75% dos valores máximos. [Publisher, Portuguese] Os dois grupos tiveram características correspondentes para a idade (62±6 vs 59±9 anos, p>.05), sexo (10/9 vs 14/5, p>0,05), IMC (26±4 vs 27±3 Kg m2, p>0,05), e pico V ˙ O 2 (72±19 vs 74±20 % pred, p>0,05), respectivamente. A inclinação V ˙ E − V ˙ CO 2 e intercepto foram significativamente diferentes para DPOC e ICC (207,2±1,4 vs 33,1±5,7 e 5,3±1,9 vs 1,7±3,6, p<0,05 para ambas), mas os valores médios da η E V ˙ foram semelhantes entre os grupos (10,2±3,4 vs 10,9±2,3%, p=0,462). As correlações entre 100% do período do exercício com 90% e 75% dele foram mais fortes para η E V ˙ (r>0,850 para ambos). [Publisher, Portuguese] A η E V ˙ é um método valioso para comparação entre doenças cardiopulmonares, com mecanismos fisiopatológicos até agora distintos, incluindo restrições ventilatórias na DPOC.
المشرفين على المادة: 142M471B3J (Carbon Dioxide)
تواريخ الأحداث: Date Created: 20240502 Date Completed: 20240502 Latest Revision: 20240731
رمز التحديث: 20240731
مُعرف محوري في PubMed: PMC11164473
DOI: 10.36660/abc.20230578
PMID: 38695473
قاعدة البيانات: MEDLINE
الوصف
تدمد:1678-4170
DOI:10.36660/abc.20230578