دورية أكاديمية

Development of a ground-based sensorimotor disorientation analog to replicate astronaut postflight experience.

التفاصيل البيبلوغرافية
العنوان: Development of a ground-based sensorimotor disorientation analog to replicate astronaut postflight experience.
المؤلفون: Moudy SC; Aegis Aerospace, Houston, TX, United States., Peters BT; KBR, Houston, TX, United States., Clark TK; Bioastronautics Laboratory, Smead Aerospace Engineering Sciences Department, University of Colorado Boulder, Boulder, CO, United States., Schubert MC; Laboratory of Vestibular NeuroAdaptation, Department of Otolaryngology Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD, United States., Wood SJ; NASA Johnson Space Center, Houston, TX, United States.
المصدر: Frontiers in physiology [Front Physiol] 2024 Apr 18; Vol. 15, pp. 1369788. Date of Electronic Publication: 2024 Apr 18 (Print Publication: 2024).
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Frontiers Research Foundation Country of Publication: Switzerland NLM ID: 101549006 Publication Model: eCollection Cited Medium: Print ISSN: 1664-042X (Print) Linking ISSN: 1664042X NLM ISO Abbreviation: Front Physiol Subsets: PubMed not MEDLINE
أسماء مطبوعة: Original Publication: Lausanne : Frontiers Research Foundation
مستخلص: The perceptual and motor coordination problems experienced following return from spaceflight reflect the sensory adaptation to altered gravity. The purpose of this study was to develop a ground-based analog that replicates similar sensorimotor impairment using a standard measures test battery and subjective feedback from experienced crewmembers. This Sensorimotor Disorientation Analog (SDA) included varying levels of sensorimotor disorientation through combined vestibular, visual, and proprioceptive disruptions. The SDA was evaluated on five previously flown astronauts to compare with their postflight experience and functional motor performance immediately (Return (R)+0 days) and +24 h (R+1) after landing. The SDA consisted of galvanic vestibular stimulation (GVS), visual disruption goggles, and a weighted suit to alter proprioceptive feedback and replicate perceived heaviness postflight. Astronauts reported that GVS alone replicated ∼50-90% of their postflight performance with the weighted suit fine-tuning the experience to replicate an additional 10%-40% of their experience. Astronauts did not report feeling that the disruption goggles represented either the visual disruptions or illusory sensations that they experienced, nor did they impact motor performance in postflight tasks similarly. Based on these results, we recommend an SDA including the GVS and the weighted suit. These results provide a more realistic and portable SDA framework to provide transient spaceflight-relevant sensorimotor disruptions for use in countermeasure testing and as a pre-flight training tool.
Competing Interests: SM was employed by Aegis Aerospace, Houston, TX, United States. BP was employed by KBR, Houston, TX. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. The author(s) declared that they were an editorial board member of Frontiers, at the time of submission. This had no impact on the peer review process and the final decision.
(Copyright © 2024 Moudy, Peters, Clark, Schubert and Wood.)
References: Aerosp Med Hum Perform. 2015 Dec;86(12 Suppl):A45-A53. (PMID: 26630195)
Brain Res. 1992 Oct 2;592(1-2):175-80. (PMID: 1450908)
OTO Open. 2017 Oct 23;1(4):2473974X17738767. (PMID: 30480196)
Front Physiol. 2022 Nov 25;13:1029161. (PMID: 36505047)
Aviat Space Environ Med. 2009 Sep;80(9):771-80. (PMID: 19750873)
Hum Factors. 1997 Sep;39(3):456-68. (PMID: 9394638)
J Vestib Res. 2018;27(5-6):243-249. (PMID: 29400689)
Eur J Appl Physiol. 2013 Apr;113(4):911-21. (PMID: 23011123)
Med Sci Sports Exerc. 2007 Mar;39(3):515-25. (PMID: 17473778)
Atten Percept Psychophys. 2012 Jan;74(1):225-38. (PMID: 22069081)
Physiother Res Int. 2020 Jan;25(1):e1814. (PMID: 31749254)
J Vestib Res. 2003;13(4-6):309-20. (PMID: 15096674)
Neurosci Lett. 2002 Apr 19;323(1):41-4. (PMID: 11911986)
Hum Perf Extrem Environ. 1998 Sep;3(1):34-6. (PMID: 12190076)
IEEE Eng Med Biol Mag. 2003 Mar-Apr;22(2):58-62. (PMID: 12733460)
Med Sci Sports Exerc. 2018 Sep;50(9):1961-1980. (PMID: 29620686)
Front Physiol. 2020 Jun 23;11:716. (PMID: 32655420)
PLoS One. 2014 Nov 19;9(11):e112131. (PMID: 25409443)
J Vestib Res. 1993 Fall;3(3):297-305. (PMID: 8275264)
Exp Brain Res. 2006 Oct;174(4):647-59. (PMID: 16763834)
J Vestib Res. 2007;17(5-6):323-32. (PMID: 18626142)
Front Syst Neurosci. 2021 Apr 27;15:658985. (PMID: 33986648)
Aerosp Med Hum Perform. 2018 Sep 1;89(9):805-815. (PMID: 30126513)
PLoS One. 2014 Oct 29;9(10):e111107. (PMID: 25354042)
J Neurophysiol. 2020 Jan 1;123(1):209-223. (PMID: 31747329)
Aviat Space Environ Med. 2011 Apr;82(4):463-6. (PMID: 21485405)
J Physiol. 2004 Jul 15;558(Pt 2):705-15. (PMID: 15181165)
J Gravit Physiol. 1997 Jul;4(2):P1-4. (PMID: 11540661)
Exp Brain Res. 2006 Jun;172(2):208-20. (PMID: 16432695)
J Physiol. 2005 Nov 1;568(Pt 3):1035-46. (PMID: 16109730)
فهرسة مساهمة: Keywords: disorientation; functional performance; sensorimotor system; spaceflight analog; vestibular system
تواريخ الأحداث: Date Created: 20240503 Latest Revision: 20240504
رمز التحديث: 20240504
مُعرف محوري في PubMed: PMC11063268
DOI: 10.3389/fphys.2024.1369788
PMID: 38699143
قاعدة البيانات: MEDLINE
الوصف
تدمد:1664-042X
DOI:10.3389/fphys.2024.1369788