دورية أكاديمية

Mid-term performance of His bundle pacing and usefulness of backup leads.

التفاصيل البيبلوغرافية
العنوان: Mid-term performance of His bundle pacing and usefulness of backup leads.
المؤلفون: Herbert J; Cardiac Pacing Unit, Department of Cardiology, University Hospital of Geneva, Rue Gabrielle-Perret-Gentil 4, CH-1211 Geneva, Switzerland., Kovacsovics A; Cardiac Pacing Unit, Department of Cardiology, University Hospital of Geneva, Rue Gabrielle-Perret-Gentil 4, CH-1211 Geneva, Switzerland., Brito R; Cardiac Pacing Unit, Department of Cardiology, University Hospital of Geneva, Rue Gabrielle-Perret-Gentil 4, CH-1211 Geneva, Switzerland., Masson N; Cardiac Pacing Unit, Department of Cardiology, University Hospital of Geneva, Rue Gabrielle-Perret-Gentil 4, CH-1211 Geneva, Switzerland., Burri H; Cardiac Pacing Unit, Department of Cardiology, University Hospital of Geneva, Rue Gabrielle-Perret-Gentil 4, CH-1211 Geneva, Switzerland.
المصدر: Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2024 Jul 02; Vol. 26 (7).
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Oxford University Press Country of Publication: England NLM ID: 100883649 Publication Model: Print Cited Medium: Internet ISSN: 1532-2092 (Electronic) Linking ISSN: 10995129 NLM ISO Abbreviation: Europace Subsets: MEDLINE
أسماء مطبوعة: Publication: 2006- : Oxford : Oxford University Press
Original Publication: London ; Philadelphia : Saunders, c1999-
مواضيع طبية MeSH: Bundle of His*/physiopathology , Cardiac Pacing, Artificial*/methods , Pacemaker, Artificial*, Humans ; Male ; Female ; Aged ; Treatment Outcome ; Middle Aged ; Aged, 80 and over ; Retrospective Studies ; Time Factors ; Electrodes, Implanted
مستخلص: Ventricular backup leads may be considered in selected patients with His bundle pacing (HBP), but it remains unknown to what extent this is useful. A total of 184 HBP patients were studied. At last follow-up, 147 (79.9%) patients retained His bundle capture at programmed output. His bundle pacing lead revision was performed in 5/36 (13.9%) patients without a backup lead and in 3/148 (2.0%) patients with a backup lead (P = 0.008). One patient without a backup lead had syncope due to atrial oversensing. Thus, implantation of ventricular backup leads may avoid lead revision and adverse events in selected HBP patients.
Competing Interests: Conflict of interest: H.B. has received speaker fees and institutional research grants from Abbott, Biotronik, Boston Scientific, Medtronic, and Microport. None of the other authors have any disclosures.
(© The Author(s) 2024. Published by Oxford University Press on behalf of the European Society of Cardiology.)
References: Europace. 2023 Feb 16;25(2):682-687. (PMID: 36413604)
Europace. 2022 Jan 4;24(1):71-164. (PMID: 34455427)
JACC Clin Electrophysiol. 2023 Aug;9(8 Pt 1):1393-1403. (PMID: 37558292)
Europace. 2023 Apr 15;25(4):1208-1236. (PMID: 37061848)
Heart Rhythm. 2019 Aug;16(8):1196-1203. (PMID: 31200093)
Europace. 2023 May 19;25(5):. (PMID: 36916199)
Ann Noninvasive Electrocardiol. 2022 Nov;27(6):e12986. (PMID: 35763445)
JACC Clin Electrophysiol. 2020 Jul;6(7):883-900. (PMID: 32703577)
Heart Rhythm. 2021 May;18(5):743-749. (PMID: 33418127)
Circ Arrhythm Electrophysiol. 2019 Feb;12(2):e006816. (PMID: 30722682)
معلومات مُعتمدة: Medical Faculty of the University of Geneva; Institutional research foundation
فهرسة مساهمة: Keywords: Adverse events; Backup lead; Conduction system pacing; His bundle pacing; Lead revision
تواريخ الأحداث: Date Created: 20240614 Date Completed: 20240702 Latest Revision: 20240802
رمز التحديث: 20240802
مُعرف محوري في PubMed: PMC11218557
DOI: 10.1093/europace/euae168
PMID: 38874449
قاعدة البيانات: MEDLINE
الوصف
تدمد:1532-2092
DOI:10.1093/europace/euae168