دورية أكاديمية

Blood Flow Capacity Assessment of End-to-Side Arterial Anastomosis In Vivo in Rats.

التفاصيل البيبلوغرافية
العنوان: Blood Flow Capacity Assessment of End-to-Side Arterial Anastomosis In Vivo in Rats.
المؤلفون: Staroverov MS; Department of Fundamental Neurosurgery, Pirogov Russian National Research Medical University, Moscow, Russia.; Federal Center of Brain Research and Neurotechnologies of the FMBA, Department of Neurosurgery, Moscow, Russia., Krylov VV; Department of Fundamental Neurosurgery, Pirogov Russian National Research Medical University, Moscow, Russia.; Federal Center of Brain Research and Neurotechnologies of the FMBA, Department of Neurosurgery, Moscow, Russia.; Department of Neurosurgery, Sklifosovsky Scientific Research Institute of Emergency Care, Moscow, Russia., Lukyanchikov VA; Department of Fundamental Neurosurgery, Pirogov Russian National Research Medical University, Moscow, Russia.; Department of Neurosurgery, Sklifosovsky Scientific Research Institute of Emergency Care, Moscow, Russia.; Department of Neurosurgery, Research Center of Neurology, Moscow, Russia., Orlov EA; Dietrich-Bonhoeffer-Klinikum, Klinik Neurochirurgie, Neubrandenburg, Germany., Veselkov AA; Department of Neurosurgery, Burdenko Neurosurgery Institute, Moscow, Russia., Dydykin SS; Department of Topographic Anatomy and Operative Surgery, Sechenov University, Moscow, Russia., Shatdler VD; Department of Fundamental Neurosurgery, Pirogov Russian National Research Medical University, Moscow, Russia.
المصدر: Asian journal of neurosurgery [Asian J Neurosurg] 2024 Jun 06; Vol. 19 (2), pp. 270-276. Date of Electronic Publication: 2024 Jun 06 (Print Publication: 2024).
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Thieme Medical and Scientific Publishers Pvt. Ltd Country of Publication: India NLM ID: 101564712 Publication Model: eCollection Cited Medium: Print ISSN: 1793-5482 (Print) NLM ISO Abbreviation: Asian J Neurosurg Subsets: PubMed not MEDLINE
أسماء مطبوعة: Publication: 2022- : UP, India : Thieme Medical and Scientific Publishers Pvt. Ltd.
Original Publication: Mumbai : Medknow Publications and Media Pvt. Ltd.
مستخلص: Introduction  The aim of this article was to assess the flow capacity of end-to-side arterial anastomosis depending on the method of its implementation. Materials and Methods  The study was conducted on 30 live Wistar rats in vivo, which were randomly divided into three groups. In each group of animals, an end-to-side microanastamosis was performed using three methods of donor artery preparation: 45 degrees (group A), 90 degrees (group B), and arteriotomy according to the "fish mouth" type (group C). The determination of flow capacity of anastomosis by measuring the blood volume flow with transonic flowmeter was performed. Results  The obtained average values after the anastomosis were, respectively, 7.335 mL/s (standard deviation [SD]: 2.0771; min: 4.05; max: 10.85), 7.36 mL/s (SD: 0.836 mi: 6.15; max: 8.75), and 6.37 mL/s (SD: 1.247; min: 5.05; max: 9.05). No statistically significant difference in the blood volume flow velocity between all types of anastomoses was obtained ( p  = 0.251). Conclusion  The flow capacity of end-to-side arterial anastomosis does not depend on the chosen method of anastomosis.
Competing Interests: Conflict of Interest None declared.
(Asian Congress of Neurological Surgeons. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ).)
References: Plast Reconstr Surg. 1980 Apr;65(4):502-3. (PMID: 7360820)
Microsurgery. 2000;20(4):173-5. (PMID: 10980516)
Neurosurgery. 2005 Jan;56(1 Suppl):75-85; discussion 75-85. (PMID: 15799795)
Neurosurg Rev. 2019 Jun;42(2):389-393. (PMID: 29536207)
J Surg Oncol. 2018 Oct;118(5):815-825. (PMID: 30196557)
Rev Neurol (Paris). 2015 Jan;171(1):31-44. (PMID: 25555850)
J Reconstr Microsurg. 1994 Mar;10(2):87-90. (PMID: 8182570)
Microsurgery. 2000;20(4):162-6. (PMID: 10980514)
Oper Neurosurg (Hagerstown). 2019 Jan 1;16(1):112-114. (PMID: 29660052)
Microsurgery. 1985;6(1):53-5. (PMID: 3990550)
J Neurosurg. 2019 May 1;130(5):1409-1425. (PMID: 31042667)
Br J Plast Surg. 1993 Oct;46(7):619-20. (PMID: 8252274)
فهرسة مساهمة: Keywords: arteriotomy in end-to-side anastomosis; blood volume flow velocity; cerebral revascularization; end-to-side anastomosis; flow capacity of end-to-side arterial anastomosis