دورية أكاديمية

Implementation of total skin electron therapy using an optional high dose rate mode on a conventional linear accelerator.

التفاصيل البيبلوغرافية
العنوان: Implementation of total skin electron therapy using an optional high dose rate mode on a conventional linear accelerator.
المؤلفون: Peters VG; Department of Medical Physics, Hamilton Regional Cancer Centre, Ontario, Canada., Jaywant SM
المصدر: Medical dosimetry : official journal of the American Association of Medical Dosimetrists [Med Dosim] 1995 Summer; Vol. 20 (2), pp. 99-104.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Elsevier Science Country of Publication: United States NLM ID: 8908862 Publication Model: Print Cited Medium: Print ISSN: 0958-3947 (Print) Linking ISSN: 18734022 NLM ISO Abbreviation: Med Dosim Subsets: MEDLINE
أسماء مطبوعة: Publication: <2000->: New York, NY : Elsevier Science
Original Publication: [Southwest Harbor, Me. : Beech Hill Pub.,
مواضيع طبية MeSH: Particle Accelerators*, Lymphoma, T-Cell, Cutaneous/*radiotherapy , Radiotherapy, High-Energy/*methods , Skin Neoplasms/*radiotherapy, Humans ; Radiotherapy Dosage ; Radiotherapy, High-Energy/instrumentation
مستخلص: A technique for total skin electron therapy (TSET) has been implemented using a standard accelerator that has been equipped with an optional special procedures mode to permit high dose-rate therapy with a 6-MeV electron beam. Patients are treated in a standing position using dual angled fields at a source to skin distance of 3.6 m. Dosimetric characteristics of the dual field technique were investigated for the 6-MeV beam as well as for a lower energy beam produced by the introduction of an acrylic beam degrader. A treatment stand, which incorporates the degrader in addition to devices used for patient support and shielding, is described. Acceptable beam uniformity and depth dose have been achieved while maintaining a low level of x-ray contamination. Treatment times are reasonably short since the output of the machine in the high-dose-rate mode is 25 Gy/min at the isocenter. Beam uniformity, dose rate, and x-ray contamination are relatively unaffected by the presence of the beam degrader if it is positioned near the treatment plane. The high dose-rate electron option is a useful treatment mode that provides the advantage of reduced treatment times while retaining proper functioning of all accelerator dosimetry systems and interlocks. Use of a dual field technique permits TSET in a treatment room of standard dimensions. The machine is easily set up for treatment, and patient setup is simplified through use of a customized support system.
تواريخ الأحداث: Date Created: 19950101 Date Completed: 19950908 Latest Revision: 20191031
رمز التحديث: 20231215
DOI: 10.1016/0958-3947(95)00013-m
PMID: 7632352
قاعدة البيانات: MEDLINE
الوصف
تدمد:0958-3947
DOI:10.1016/0958-3947(95)00013-m