دورية أكاديمية

Marginal bone level buccal to mandibular molars in digital radiographs from charge-coupled device and storage phosphor systems. An in vitro study.

التفاصيل البيبلوغرافية
العنوان: Marginal bone level buccal to mandibular molars in digital radiographs from charge-coupled device and storage phosphor systems. An in vitro study.
المؤلفون: Borg E; Department of Oral Diagnostic Radiology, Faculty of Odontology, University of Göteborg, Sweden., Gröndahl K, Gröndahl HG
المصدر: Journal of clinical periodontology [J Clin Periodontol] 1997 May; Vol. 24 (5), pp. 306-12.
نوع المنشور: Comparative Study; Journal Article
اللغة: English
بيانات الدورية: Publisher: Wiley-Blackwell Country of Publication: United States NLM ID: 0425123 Publication Model: Print Cited Medium: Print ISSN: 0303-6979 (Print) Linking ISSN: 03036979 NLM ISO Abbreviation: J Clin Periodontol Subsets: MEDLINE
أسماء مطبوعة: Publication: Malden, MA : Wiley-Blackwell
Original Publication: Copenhagen, Munksgaard.
مواضيع طبية MeSH: Radiography, Dental, Digital*, Alveolar Bone Loss/*diagnostic imaging , Radiographic Image Enhancement/*instrumentation , Radiography, Dental/*instrumentation, Alveolar Bone Loss/pathology ; Humans ; Mandible/diagnostic imaging ; Radiography, Dental/methods ; Reproducibility of Results ; X-Ray Intensifying Screens
مستخلص: The aim of this in vitro study was to compare bone loss measurements in the furcation area of mandibular molars in digital radiographs from a CCD-(Sens-A-Ray) and a storage phosphor (Digora) system, 10 1st and 7 2nd mandibular molars, with intact lingual but reduced buccal bone with furcation involvements, were used. Radiographs were first taken with lead markers at the most apical part of the buccal bone and at the cemento-enamel junction. These radiographs were used to establish a radiographically true distance between the CEJ and the buccal bone level. The lead marker at the CEJ served as a reference point for the observers' subsequent estimates of the extent of bone removed, which were made in radiographs without lead markers at the bone level. 1 exposure (400 ms) for the CCD- and 5 (160 ms, 200 ms, 250 ms, 320 ms, 400 ms) for the storage phosphor system were used. Measurements were made in unprocessed (original) and processed images (contrast enhanced and/or high pass filtered). The results showed underestimation of bone loss, but smaller than previously reported for film radiographs. No significant difference was found between the 2 systems when compared at the same exposure. Nor were any significant differences found between unprocessed and processed images or between storage phosphor images from different exposures. We conclude that digital radiographs are comparable to film based radiographs for measurement of buccal bone loss but that lower exposures can be used, especially with the storage phosphor system.
تواريخ الأحداث: Date Created: 19970501 Date Completed: 19970708 Latest Revision: 20190831
رمز التحديث: 20231215
DOI: 10.1111/j.1600-051x.1997.tb00762.x
PMID: 9178109
قاعدة البيانات: MEDLINE
الوصف
تدمد:0303-6979
DOI:10.1111/j.1600-051x.1997.tb00762.x