Pulsatile and nonpulsatile extracorporeal circulation using Capiox E terumo oxygenator: a comparison study with Ultrox and Maxima membrane oxygenators.

التفاصيل البيبلوغرافية
العنوان: Pulsatile and nonpulsatile extracorporeal circulation using Capiox E terumo oxygenator: a comparison study with Ultrox and Maxima membrane oxygenators.
المؤلفون: Minami K; Department of Thoracic and Cardiovascular Surgery, Heart Center North Rhine-Westfalia, University of Bochum, Germany., Bairaktaris A, Murray E, Weitkemper H, Dramburg W, Körfer R
المصدر: The Journal of cardiovascular surgery [J Cardiovasc Surg (Torino)] 1997 Jun; Vol. 38 (3), pp. 227-32.
نوع المنشور: Clinical Trial; Comparative Study; Journal Article; Randomized Controlled Trial
اللغة: English
بيانات الدورية: Publisher: Edizioni Minerva Medica Country of Publication: Italy NLM ID: 0066127 Publication Model: Print Cited Medium: Print ISSN: 0021-9509 (Print) Linking ISSN: 00219509 NLM ISO Abbreviation: J Cardiovasc Surg (Torino) Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Torino : Edizioni Minerva Medica
مواضيع طبية MeSH: Coronary Artery Bypass* , Pulsatile Flow*, Cardiopulmonary Bypass/*instrumentation , Oxygenators, Membrane/*standards, Blood Gas Analysis ; Equipment Design ; Hemoglobins/analysis ; Humans ; L-Lactate Dehydrogenase/blood ; Polypropylenes ; Prospective Studies ; Water-Electrolyte Balance
مستخلص: An open randomised, prospective study was undertaken on 90 patients who underwent routine myocardial revascularization. The aim of the study was to demonstrate that the Capiox E polypropylene fiber membrane oxygenator with a conventional single pulsatile/nonpulsatile blood pump for cardiopulmonary bypass (CPB) was comparable in performance to that of the Maxima and the Ultrox membrane oxygenators using a double pump system. The patients were divided into six groups according to perfusion mode and oxygenator type. Laboratory parameters, fluid balance and oxygenation was examined at set times before during and after cardiopulmonary bypass. Net fluid input was lower in the Capiox E groups regardless of perfusion mode: 2932 +/- 562 ml (Capiox E), compared to 3646 +/- 531 ml (Ultrox) and 3593 +/- 582 ml (Maxima). Net fluid balance 1288 +/- 534 ml was lowest in the Capiox/NP group, compared to 1604 +/- 460 ml (Ultrox/NP) and 1881 +/- 594 ml (Maxima/NP), (p < 0.05). The higher net fluid balance in the Capiox E/PP group 1649 +/- 580 ml compared to 1592 +/- 583 ml (Ultrox E/PP) and 1494 +/- 542 ml (Maxima/PP) was attributed to a technicality whereby the recommended priming volume of the Capiox E oxygenator was exceeded for safety reasons. The values of plasma free Hb were slightly higher in the PP than NP groups: Maxima/PP 80 mg/dl, /NP 50 mg/dl; Ultrox/PP 62 mg/dl, /NP 48 mg/dl; Capiox E/PP 55 mg/dl, /NP 48 mg/dl. The FiO2 was higher in the Capiox E groups 0.77 (PP) and 0.88 (NP) compared to Maxima/PP (0.66), /NP (0.65) and Ultrox/PP (0.64), /NP (0.63). Reciprocally, the venous saturation was higher in the Ultrox and Maxima groups compared to Capiox E at end of CPB. The study demonstrated that the CapioxE oxygenator with a single blood pump system can compare to the Maxima and Ultrox oxygenators with a double blood pump for CPB with regard to blood handling, oxygenation and fluid balance in routine cardiac surgery.
المشرفين على المادة: 0 (Hemoglobins)
0 (Polypropylenes)
EC 1.1.1.27 (L-Lactate Dehydrogenase)
تواريخ الأحداث: Date Created: 19970601 Date Completed: 19970731 Latest Revision: 20161026
رمز التحديث: 20240628
PMID: 9219471
قاعدة البيانات: MEDLINE