Development of novel electrospun absorbable polycaprolactone (PCL) scaffolds for hernia repair applications.

التفاصيل البيبلوغرافية
العنوان: Development of novel electrospun absorbable polycaprolactone (PCL) scaffolds for hernia repair applications.
المؤلفون: Ebersole GC, Buettmann EG, Macewan MR, Tang ME, Frisella MM, Matthews BD, Deeken CR, Ebersole, Gregory C, Buettmann, Evan G, MacEwan, Matthew R, Tang, Michael E, Frisella, Margaret M, Matthews, Brent D, Deeken, Corey R
المصدر: Surgical Endoscopy & Other Interventional Techniques; Oct2012, Vol. 26 Issue 10, p2717-2728, 12p
مستخلص: Introduction: Permanent/nonresorbable hernia repair materials rely on profibrotic wound healing, and repair sites are commonly composed of disorganized tissue with inferior mechanical strength and risk of reherniation. Resorbable electrospun scaffolds represent a novel class of biomaterials, which may provide a unique platform for the design of advanced soft tissue repair materials. These materials are simple, inexpensive, nonwoven materials composed of polymer fibers that readily mimic the natural extracellular matrix. The primary goal of the present study was to evaluate the physiomechanical properties of novel electrospun scaffolds to determine their suitability for hernia repair. Based on previous experimentation, scaffolds possessing ≥ 20 N suture retention strength, ≥ 20 N tear resistance, and ≥ 50 N/cm tensile strength are appropriate for hernia repair.Methods: Six novel electrospun scaffolds were fabricated by varying combinations of polymer concentration (10-12 %) and flow rate (3.5-10 mL/h). Briefly, poly(ε-caprolactone) (PCL) was dissolved in a solvent mixture and electrospun onto a planar metal collector, yielding sheets with randomly oriented fibers. Physiomechanical properties were evaluated through scanning electron microscopy, laser micrometry, and mechanical testing.Results: Scanning electron micrographs demonstrated fiber diameters ranging from 1.0 ± 0.1 μm (10 % PCL, 3.5 mL/h) to 1.5 ± 0.2 μm (12 % PCL, 4 mL/h). Laser micrometry demonstrated thicknesses ranging from 0.72 ± 0.07 mm (12 % PCL, 10 mL/h) to 0.91 ± 0.05 mm (10 % PCL, 3.5 mL/h). Mechanical testing identified two scaffolds possessing suture retention strengths ≥ 20 N (12 % PCL, 10 mL/h and 12 % PCL, 6 mL/h), and no scaffolds possessing tear resistance values ≥ 20 N (range, 4.7 ± 0.9 N to 10.6 ± 1.8 N). Tensile strengths ranged from 35.27 ± 2.08 N/cm (10 % PCL, 3.5 mL/h) to 81.76 ± 15.85 N/cm (12 % PCL, 4 mL/h), with three scaffolds possessing strengths ≥ 50 N/cm (12 % PCL, 10 mL/h; 12 % PCL, 6 mL/h; 12 % PCL, 4 mL/h).Conclusions: Two electrospun scaffolds (12 % PCL, 10 mL/h and 12 % PCL, 6 mL/h) possessed suture retention and tensile strengths appropriate for hernia repair, justifying evaluation in a large animal model. Additional studies examining advanced methods of fabrication may further improve the unique properties of these scaffolds, propelling them into applications in a variety of clinical settings. [ABSTRACT FROM AUTHOR]
Copyright of Surgical Endoscopy & Other Interventional Techniques is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index