دورية أكاديمية

High resolution myocardial magnetic resonance stress perfusion imaging at 3 T using a 1 M contrast agent.

التفاصيل البيبلوغرافية
العنوان: High resolution myocardial magnetic resonance stress perfusion imaging at 3 T using a 1 M contrast agent.
المؤلفون: Klumpp BD, Seeger A, Doesch C, Doering J, Hoevelborn T, Kramer U, Fenchel M, Gawaz MP, Claussen CD, Miller S, Klumpp, Bernhard D, Seeger, Achim, Doesch, Christina, Doering, Joerg, Hoevelborn, Tobias, Kramer, Ulrich, Fenchel, Michael, Gawaz, Meinrad P, Claussen, Claus D, Miller, Stephan
المصدر: European Radiology; Mar2010, Vol. 20 Issue 3, p533-541, 9p
مستخلص: Objective: Stress perfusion magnetic resonance imaging (MSPMRI) is an established technique for the assessment of myocardial perfusion. Shortcomings at 1.5 T are low signal to noise ratio (SNR) and contrast to noise ratio (CNR). One approach to overcome these shortcomings is to increase field strength and contrast concentration. The aim of our study was to investigate the diagnostic capability of high resolution MSPMRI at 3-T field strength using a 1 M contrast agent.Material and Methods: Fifty-seven patients (62.3 +/- 11.0 years) with symptoms of coronary artery disease (CAD) were examined at 3 T. MMRSPI was assessed using a 2D saturation recovery gradient echo (SR GRE) sequence in short axis orientation (TR 1.9 ms, TE 1.0 ms, flip 12 degrees , 0.1 mmol gadobutrol/kg body weight (bw), 140 microg adenosine/kg bw/min). Perfusion images were assessed visually and semiquantitatively (upslope, peak signal intensity (SI), and myocardial perfusion reserve index (MPRI)). Standard of reference was invasive coronary angiography.Results: Stress-induced hypoperfusion was found in 43 patients. Sensitivity for hemodynamically relevant CAD (stenoses greater than 70%) was 95%/98%, specificity 80%/87%, diagnostic accuracy 91%/95% (reader 1/reader 2). The MPRI was significantly lower in hypoperfused myocardium (1.3 +/- 0.2) compared with normal myocardium (2.6 +/- 0.7).Conclusion: High resolution MMRSPI at 3 T using 1 M contrast agent under daily routine conditions provides reliable detection of stress-induced myocardial hypoperfusion with higher diagnostic accuracy than 1.5-T conditions. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:09387994
DOI:10.1007/s00330-009-1580-6