Effect of Different Levels of Pressure Support and Proportional Assist Ventilation on Breathing Pattern, Work of Breathing and Gas Exchange in Mechanically Ventilated Hypercapnic COPD Patients with Acute Respiratory Failure.

التفاصيل البيبلوغرافية
العنوان: Effect of Different Levels of Pressure Support and Proportional Assist Ventilation on Breathing Pattern, Work of Breathing and Gas Exchange in Mechanically Ventilated Hypercapnic COPD Patients with Acute Respiratory Failure.
المؤلفون: F. Passam, S. Hoing, G. Prinianakis, N. Siafakas, J. Milic-Emili, D. Georgopoulos
المصدر: Respiration; Jul/Aug2003, Vol. 70 Issue 4, p355, 7p
مصطلحات موضوعية: VENTILATION, RESPIRATORY insufficiency, BLOOD gases, ADULT respiratory distress syndrome, PULMONARY manifestations of general diseases
مستخلص: Background: Proportional assist ventilation (PAV) has been shown to maintain better patient-ventilator synchrony than pressure support ventilation (PSV); however, its clinical advantage regarding invasive ventilation of COPD patients has not been clarified. Objectives: To compare the effect of PAV and PSV on respiratory parameters of hypercapnic COPD patients with acute respiratory failure (ARF). Methods: Nine intubated hypercapnic COPD patients were placed on the PAV or PSV mode in random sequence. For each mode, four levels (L1–L4) of support were applied. At each level, blood gases, flow, tidal volume (VT), airway pressure (Paw), esophageal pressure (Pes) (n = 7), patient respiratory rate (fp), ventilator rate (fv), missing efforts (ME = fp – fv) were measured. Results: We found increases in ME with increasing levels of PSV but not with PAV. PO2 and VT increased whereas PCO2 decreased significantly with increasing levels of PSV (p < 0.05). With PAV, PCO2 decreased and VT increased significantly only at L4 whereas PO2 increased from L1 to L4. Runaways were observed at L3 and L4 of PAV. The pressure-time product (PTP) was determined for effective and missing breaths. The mean total PTP per minute (of effective plus missing breaths) was 160 ± 57 cm H2O/s·min in PSV and 194 ± 60 cm H2O/s·min in PAV. Conclusion: We conclude that in COPD patients with hypercapnic ARF, with increasing support, PSV causes the appearance of ME whereas PAV develops runaway phenomena, due to the different patient-ventilator interaction; however, these do not limit the improvement of blood gases with the application of both methods.Copyright © 2003 S. Karger AG, Basel [ABSTRACT FROM AUTHOR]
Copyright of Respiration is the property of Karger AG and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)