Clinical evaluation of complete solo surgery with the "ViKY®" robotic laparoscope manipulator.

التفاصيل البيبلوغرافية
العنوان: Clinical evaluation of complete solo surgery with the "ViKY®" robotic laparoscope manipulator.
المؤلفون: Takahashi, Masahiro, Takahashi, Masanori, Nishinari, Naoto, Matsuya, Hideki, Tosha, Tsutomu, Minagawa, Yukihiro, Shimooki, Osamu, Abe, Tadashi
المصدر: Surgical Endoscopy & Other Interventional Techniques; Feb2017, Vol. 31 Issue 2, p981-986, 6p
مصطلحات موضوعية: SURGICAL robots, OPERATIVE surgery, MEDICAL equipment, SURGEONS, ENDOSCOPES
مستخلص: Background: Advancement in both surgical technique and medical equipment has enabled solo surgery. ViKY® Endoscope Positioning System (ViKY®) is a robotic system that remotely controls an endoscope and provides direct vision control to the surgeon. Here, we report our experience with ViKY®-assisted solo surgery.Methods: We retrospectively examined 25 cases of solo surgery TAPP with ViKY®. ViKY® was setup by the surgeon alone, and the setup duration was determined as the time at which the side rail was positioned and that when the endoscope was installed. For assessing the control unit, the number of false movements was counted. We compared the operative results between ViKY®-assisted solo surgery TAPP and the conventional method with an assistant.Results: The average time to set up ViKY® was 7.9 min. The average number of commands for ViKY® during surgery was 98.3, and the average number of errors and no response of control unit was 7.9. The mean duration of surgery was 136 min for the ViKY® group, including the setup time, and 117 min for the conventional method. No case required an assistant during the operation. There was also no difference between the two groups with regard to postoperative complications and the rate of recurrence.Conclusions: ViKY® proved reliable in recognizing orders with very few failures, and the operations were performed safely and were comparable to the conventional operations with assistants. Solo surgery with ViKY® was beneficial in this clinical evaluation. [ABSTRACT FROM AUTHOR]
Copyright of Surgical Endoscopy & Other Interventional Techniques is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:18666817
DOI:10.1007/s00464-016-5058-8