دورية أكاديمية

4D ultrasound study of fetal movement early in the second trimester of pregnancy.

التفاصيل البيبلوغرافية
العنوان: 4D ultrasound study of fetal movement early in the second trimester of pregnancy.
المؤلفون: Sajapala, Suraphan, Mohamed Ahmed Mostafa AboEllail, Kenji Kanenishi, Nobuhiro Mori, Genzo Marumo, Toshiyuki Hata
المصدر: Journal of Perinatal Medicine; Aug2017, Vol. 45 Issue 6, p737-743, 7p, 1 Color Photograph, 2 Charts, 3 Graphs
مصطلحات موضوعية: STATISTICAL correlation, FETAL movement, FETAL ultrasonic imaging, NEUROPHYSIOLOGY, SECOND trimester of pregnancy, PROBABILITY theory, RESEARCH evaluation, THREE-dimensional imaging, INTER-observer reliability, DATA analysis software
مصطلحات جغرافية: JAPAN
مستخلص: Aim: To assess the frequency of fetal movement and reproducibility of fetal movement counting in normal singleton pregnancies early in the second trimester using fourdimensional (4D) ultrasound. Methods: Twenty-nine singleton pregnancies were studied for 15 min employing 4D ultrasound at 14-16 (19 cases) and 17-19 (10 cases) weeks of gestation. The frequencies of eight fetal movements (head anteflexion, head retroflexion, body rotation, hand to face movement, general movement, isolated arm movement, isolated leg movement and mouthing movement) were evaluated. Results: The most frequent fetal movements were isolated arm movements at 14-16 and 17-19 weeks'gestation. There was a significant difference only in the frequency of mouthing movement between 14-16 and 17-19 weeks'gestation (P < 0.05). All fetal movements showed intra- and inter-class correlation coefficients greater than 0.87, with good intra- and inter-observer agreements. Conclusion: The difference in the frequency of mouthing movement at 14-16 and 17-19 weeks'gestation may be due to increasing fetal swallowing because of the increasing amniotic fluid early in the second trimester of pregnancy. To the best of our knowledge, this is the first study on the reproducibility assessment of fetal movement counting using 4D ultrasound. However, the data and their interpretation in the present study should be taken with some degree of caution because of the small number of subjects studied. Further studies involving a larger sample size are needed to assess the reproducibility of fetal movement counting using 4D ultrasound. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Perinatal Medicine is the property of De Gruyter and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:03005577
DOI:10.1515/jpm-2016-0250