Advanced small- and wide-angle x-ray scattering beamline for frontier research in biological structures at the Taiwan photon source.

التفاصيل البيبلوغرافية
العنوان: Advanced small- and wide-angle x-ray scattering beamline for frontier research in biological structures at the Taiwan photon source.
المؤلفون: Din-Goa Liu, Chien-Hung Chang, Ming-Han Lee, Chin-Yen Liu, Chia-Feng Chang, Liang-Chih Chiang, Ching-Shiang Hwang, Jui-Che Huang, Albert Sheng, Chien-Kuang Kuan, Yi-Qi Yeh, Chun-Jen Su, Kuei-Fen Liao, Wei-Ru Wu, Orion Shih, U-Ser Jeng
المصدر: AIP Conference Proceedings; 2018, Vol. 2054 Issue 1, p060021-1-060021-6, 6p
مصطلحات موضوعية: SMALL-angle X-ray scattering, WIGGLER magnets, ABSORPTION, BIOMACROMOLECULES, MONOCHROMATORS, DEFLECTION (Light)
مستخلص: The TPS 13A biological small-angle X-ray scattering (BioSAXS) beamline under construction is equipped with 4-m IU24 undulator for X-rays in the energy range of E = 4-23 keV (covering the K-edge absorptions from Ca to Ru). The beamline aims for cutting-edge researches in biomacromolecular structures and kinetics, in solid and solution, covering a wide length scale from atomic to micrometer scale and time resolution down to μs. To achieve the goals, the beamline integrates double-multilayer and double-crystal monochromators (DMM/DCM) to have an option of high flux of 4 × 1014 photons/s or a high energy resolution of ΔE/E = 1.5×10−4. The DCM together with a horizontal four-bounce crystal collimator (4BCC) will be implanted for low beam divergence to perform 2D ultra-SAXS (USAXS). To keep a common X-ray beam path of the operation modes, DMM and DCM are integrated into one rotating cradle in a same chamber for a common beam exit. Microbeam with reasonable beam divergence for SAXS/WAXS structural mapping will be realized with a virtual source defined by a set of high precision/stability slits and another set of K-B mirrors for a focus at the sample position with a demagnification close to 1.3:1. Two beam position monitors, with intensity and position feedbacks respectively to the virtual source slits and the 4BCC and a vertical deflection mirror, are used mainly to stabilize microbeam intensity and position within 1 μm in the vertical and horizontal directions. This TPS 13A BioSAXS beamline will be commissioning at the end of 2019. [ABSTRACT FROM AUTHOR]
Copyright of AIP Conference Proceedings is the property of American Institute of Physics and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:0094243X
DOI:10.1063/1.5084652