دورية أكاديمية

Extended diagnosis of purine and pyrimidine disorders from urine: LC MS/MS assay development and clinical validation.

التفاصيل البيبلوغرافية
العنوان: Extended diagnosis of purine and pyrimidine disorders from urine: LC MS/MS assay development and clinical validation.
المؤلفون: Monostori, Péter, Klinke, Glynis, Hauke, Jana, Richter, Sylvia, Bierau, Jörgen, Garbade, Sven F., Hoffmann, Georg F., Langhans, Claus-Dieter, Haas, Dorothea, Okun, Jürgen G.
المصدر: PLoS ONE; 2/28/2019, Vol. 14 Issue 2, p1-17, 17p
مصطلحات موضوعية: PYRIMIDINE metabolism, URINALYSIS, KIDNEY stones diagnosis, LIQUID chromatography-mass spectrometry, CLINICAL trials
مستخلص: Background and aims: Inborn errors of purine and pyrimidine metabolism are a diverse group of disorders with possible serious or life-threatening symptoms. They may be associated with neurological symptoms, renal stone disease or immunodeficiency. However, the clinical presentation can be nonspecific and mild so that a number of cases may be missed. Previously published assays lacked detection of certain diagnostically important biomarkers, including SAICAr, AICAr, beta-ureidoisobutyric acid, 2,8-dihydroxyadenine and orotidine, necessitating the use of separate assays for their detection. Moreover, the limited sensitivity for some analytes in earlier assays may have hampered the reliable detection of mild cases. Therefore, we aimed to develop a liquid chromatography–tandem mass spectrometry (LC-MS/MS) assay that allows the simultaneous and sensitive detection of an extended range of purine and pyrimidine biomarkers in urine. Methods: The assay was developed and validated using LC-MS/MS and clinically tested by analyzing ERNDIM Diagnostic Proficiency Testing (DPT) samples and further specimens from patients with various purine and pyrimidine disorders. Results: Reliable determination of 27 analytes including SAICAr, AICAr, beta-ureidoisobutyric acid, 2,8-dihydroxyadenine and orotidine was achieved in urine following a simple sample preparation. The method clearly distinguished pathological and normal samples and differentiated between purine and pyrimidine defects in all clinical specimens. Conclusions: A LC-MS/MS assay allowing the simultaneous, sensitive and reliable diagnosis of an extended range of purine and pyrimidine disorders has been developed. The validated method has successfully been tested using ERNDIM Diagnostic Proficiency Testing (DPT) samples and further clinical specimens from patients with various purine and pyrimidine disorders. Sample preparation is simple and assay duration is short, facilitating an easier inclusion of the assay into the diagnostic procedures. [ABSTRACT FROM AUTHOR]
Copyright of PLoS ONE is the property of Public Library of Science and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:19326203
DOI:10.1371/journal.pone.0212458