دورية أكاديمية

Microphysiological heart–liver body-on-a-chip system with a skin mimic for evaluating topical drug delivery.

التفاصيل البيبلوغرافية
العنوان: Microphysiological heart–liver body-on-a-chip system with a skin mimic for evaluating topical drug delivery.
المؤلفون: Pires de Mello, Camilly P., Carmona-Moran, Carlos, McAleer, Christopher W., Perez, Julian, Coln, Elizabeth A., Long, Christopher J., Oleaga, Carlota, Riu, Anne, Note, Reine, Teissier, Silvia, Langer, Jessica, Hickman, James J.
المصدر: Lab on a Chip; 2/21/2020, Vol. 20 Issue 4, p749-759, 11p
مصطلحات موضوعية: SKIN permeability, DRUG toxicity, ACETAMINOPHEN, DICLOFENAC, SKIN absorption, SKIN, DRUG efficacy, TEST systems
مستخلص: Body-on-a-chip in vitro systems are a promising technology that aims to increase the predictive power of drug efficacy and toxicity in humans when compared to traditional animal models. Here, we developed a new heart–liver body-on-a-chip system with a skin surrogate to assess the toxicity of drugs that are topically administered. In order to test the utility of the system, diclofenac, ketoconazole, hydrocortisone and acetaminophen were applied topically through a synthetic skin surrogate (Strat-M membrane) and the toxicity results were compared to those of acute drug exposure from systemically applying the compounds. The heart–liver system was successful in predicting the effects for both cardiac and liver functions changes due to the compounds. The difference in the concentrations of drugs applied topically compared to systemically indicates that the barrier properties of the skin surrogate were efficient. One important advantage of this heart–liver system was the capability of showing differential effects of acute and chronic drug exposure which is necessary as part of the International Conference in Harmonisation (ICH) tri-partate guidelines. In conclusion, this work indicates a promising heart–liver body-on-a-chip system that can be used for the assessment of potential drug toxicity from dermal absorption as well as evaluate transport dynamics through the skin in the same system. [ABSTRACT FROM AUTHOR]
Copyright of Lab on a Chip is the property of Royal Society of Chemistry and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:14730197
DOI:10.1039/c9lc00861f