Quantification of Cardiac Output with Phase Contrast Magnetic Resonance Imaging in Patients with Pulmonary Hypertension.

التفاصيل البيبلوغرافية
العنوان: Quantification of Cardiac Output with Phase Contrast Magnetic Resonance Imaging in Patients with Pulmonary Hypertension.
المؤلفون: Po, Jose Ricardo, Matthew Tong, Meeran, Talha, Potluri, Alekhya, Raina, Amresh, Doyle, Mark, Biederman, Robert
المصدر: Journal of Clinical Imaging Science; May2020, p1-7, 7p
مصطلحات موضوعية: CARDIAC output, PHASE contrast magnetic resonance imaging, PULMONARY hypertension, CARDIAC magnetic resonance imaging
مستخلص: Objective: The purpose of the study is to compare phase contrast (PC) imaging with invasive measurements of cardiac output (CO) in patients with pulmonary hypertension (PH). Materials and Methods: We analyzed 81 cases with PH who underwent cardiac magnetic resonance imaging and right heart catheterization (RHC). Measurement of CO and stroke volume (SV) by cardiac magnetic resonance (CMR) was performed by PC imaging of the proximal aorta (Ao) and pulmonary artery (Pa) and by RHC using the Fick and thermodilution (TD) methods. Results: There was good correlation in CO measurements between PC and RHC; however, there was better correlation with SV measurements; Fick-TD (r=0.85), PC-TD (Ao r=0.77, Pa r=0.79), and PC-Fick (Ao r = 0.73, Pa r = 0.78). Bland-Altman analysis of SV showed that Pa PC had slightly lower standard deviation than Ao PC; PC-Fick (Pa SD = 15.11 vs. Ao SD = 16.4 ml) and PC-TD (Pa SD = 16.99 ml vs. Ao SD = 17.4 ml) while Fick-TD had the lowest (SD = 14.4 ml). Compared to Fick, measurement of SV with Ao PC (4.12 ml) and Pa PC (0.22 ml) both had lower mean difference than TD (11.1 ml). Conclusion: Non-invasive measurement of CO and SV using PC-CMR correlates well with invasive measurement using RHC. Our study showed that PC-CMR had high accuracy and precision when compared to Fick. Among all the modalities, PC-CMR contributed the least amount of variation in measurements. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Clinical Imaging Science is the property of Scientific Scholar LLC and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:21567514
DOI:10.25259/JCIS_36_2020