Field measurement and verification of the UHF calibration platform based on the GTEM cell.

التفاصيل البيبلوغرافية
العنوان: Field measurement and verification of the UHF calibration platform based on the GTEM cell.
المؤلفون: Yi-fan, Wang, Jin-long, Gong, Jian-ling, Jiang, Zhi-guo, Tang, Fei, Wang
المصدر: Journal of Engineering; Apr2019, Vol. 2019 Issue 4, p1585-1588, 4p
مصطلحات موضوعية: PARTIAL discharges, ELECTROMAGNETISM, ELECTRIC power, ELECTRIC field strength, MONOPOLE antennas
مستخلص: The measurable electric field of the partial discharge ultra-high-frequency (PD UHF) detection system calibrated by a gigahertz transverse electromagnetic cell (GTEM) has been used as a key indicator to evaluate the performance of the detection system and regarded as the electric power standard. In this study, the sweep frequency and pulse signal were injected to the GTEM cell, and then the waveform and amplitude of the calibrated field strength were calculated by using the transfer function and voltage response of the monopole antennas. In the case of sweep frequency, comparing the measured result of the Narda field strength metre and the calculated result of monopole antennas, the error was found to be <8%, which verifies the correctness of the calibration of the monopole antennas to the steady-state electric field in the GTEM. In the case of pulse injection, comparing the simulation result of computer simulation technology and the calculated result of monopole antennas, the error of the peak of the field strength was found to be 1.7%, which verifies the correctness of the calibration of the monopole antennas to the pulse electric field in the GTEM. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Engineering is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:20513305
DOI:10.1049/joe.2018.8882