دورية أكاديمية

Simultaneous detection of multiple bacterial and viral aquatic pathogens using a fluorogenic loop‐mediated isothermal amplification‐based dual‐sample microfluidic chip.

التفاصيل البيبلوغرافية
العنوان: Simultaneous detection of multiple bacterial and viral aquatic pathogens using a fluorogenic loop‐mediated isothermal amplification‐based dual‐sample microfluidic chip.
المؤلفون: Zhou, Qian‐Jin, Lu, Jian‐Fei, Su, Xiu‐Rong, Jin, Jing‐Lei, Li, Shang‐Yang, Zhou, Yan, Wang, Lei, Shao, Xin‐Bin, Wang, Yao‐Hua, Yan, Mao‐Cang, Li, Ming‐Yun, Chen, Jiong
المصدر: Journal of Fish Diseases; Apr2021, Vol. 44 Issue 4, p401-413, 13p
مصطلحات موضوعية: VIBRIO harveyi, WHITE spot syndrome virus, PATHOGENIC microorganisms, BACTERIAL DNA, EDWARDSIELLA tarda, RECOMBINANT DNA
مستخلص: Rapid and user‐friendly diagnostic tests are necessary for early diagnosis and immediate detection of diseases, particularly for on‐site screening of pathogenic microorganisms in aquaculture. In this study, we developed a dual‐sample microfluidic chip integrated with a real‐time fluorogenic loop‐mediated isothermal amplification assay (dual‐sample on‐chip LAMP) to simultaneously detect 10 pathogenic microorganisms, that is Aeromonas hydrophila, Edwardsiella tarda, Vibrio harveyi, V. alginolyticus, V. anguillarum, V. parahaemolyticus, V. vulnificus, infectious hypodermal and haematopoietic necrosis virus, infectious spleen and kidney necrosis virus, and white spot syndrome virus. This on‐chip LAMP provided a nearly automated protocol that can analyse two samples simultaneously, and the tests achieved limits of detection (LOD) ranging from 100 to 10–1 pg/μl for genomic DNA of tested bacteria and 10–4 to 10–5 pg/μl for recombinant plasmid DNA of tested viruses, with run times averaging less than 30 min. The coefficient of variation for the time‐to‐positive value was less than 10%, reflecting a robust reproducibility. The clinical sensitivity and specificity were 93.52% and 85.53%, respectively, compared to conventional microbiological or clinical methods. The on‐chip LAMP assay provides an effective dual‐sample and multiple pathogen analysis, and thus would be applicable to on‐site detection and routine monitoring of multiple pathogens in aquaculture. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Fish Diseases is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:01407775
DOI:10.1111/jfd.13325