Ceramic-on-ceramic versus ceramicon-polyethylene in total hip arthroplasty: a comparative study at a minimum of 13 years follow-up.

التفاصيل البيبلوغرافية
العنوان: Ceramic-on-ceramic versus ceramicon-polyethylene in total hip arthroplasty: a comparative study at a minimum of 13 years follow-up.
المؤلفون: Giuseppe, Malerba, Mattia, Basilico, Nadia, Bonfglio, Rafaele, Vitiello, Pasquale, Ruberto, Stefano, D’Adamio, Mattia, Sirgiovanni, Vincenzo, De Santis, Giulio, Maccauro
المصدر: BMC Musculoskeletal Disorders; 12/30/2021 Supplement 2, Vol. 22 Issue 2, p1-8, 8p
مستخلص: Background: Nowadays hip replacement is one of the most successful surgery in terms of clinical outcome and patient’s satisfaction. Therefore, the choice of biomaterials in hip replacement is increasingly important with the aim of obtaining a long-term satisfaction of patient and a greater survivorship of the implants. Ceramic-on-polyethylene (COP) and ceramic-on-ceramic (CoC) bearings are two common coupling used in total hip arthroplasty. The aim of this retrospective study was to compare clinical and radiological outcomes between patients treated using CoC and CoP THA at a mean follow-up of 15 years. Methods: 86 patients, average age 65.6, were included in the study: 43 in group A bearing CoC and 43 in group B bearing CoP. Minimum follow-up was 13 years. Primary outcome was a clinical evaluation assessed by HOOS and SF-12 questionnaires. Secondary outcome was a radiological evaluation on a A-P pelvis x-ray calculating acetabular cup inclination and anteversion and detecting osteolysis. Result: After a multivariate analysis was performed, our results show clinical outcomes in group B signifcantly better than in group A: statistically signifcant value (p<0,05) was found in the mean HOOS-symptoms subscale (83.0±15.4 in Group A vs 90.3±12.2 in group B) in the SF-12 physical component score (39.7±11.0 in Group A vs 48.1±10.1 in group B) and in HOOS (79.0±16 in Group A vs 87.0±16 in group B). 3 squeaking was found in group A. The calculated mean acetabular cup inclination value was 44,87 in group A and 44,5 in group B and the mean socket version was 17,54 in group A and 15,10 in group B. No signifcant statistically relationship between radiographic parameters analyzed and clinical outcomes was noted. Conclusion: The current results provide us important information about the THA long-term outcome. CoP ofered signifcantly better results compared with CoC at long-term follow up, and thus it should be considered in the choose of bearing in THA. [ABSTRACT FROM AUTHOR]
Copyright of BMC Musculoskeletal Disorders is the property of BioMed Central and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:14712474
DOI:10.1186/s12891-021-04950-x