دورية أكاديمية

Adaptive predictive control of flywheel storage for transient stability enhancement of a wind penetrated power system.

التفاصيل البيبلوغرافية
العنوان: Adaptive predictive control of flywheel storage for transient stability enhancement of a wind penetrated power system.
المؤلفون: Kumar, Abdul Waheed, Mufti, Mairaj‐ud din, Zargar, Mubashar Y.
المصدر: International Journal of Energy Research; Apr2022, Vol. 46 Issue 5, p6654-6671, 18p
مصطلحات موضوعية: ADAPTIVE control systems, ELECTRIC transients, FLYWHEELS, ENERGY storage, PREDICTIVE control systems, INDUCTION generators, ELECTRIC power system stability
مصطلحات جغرافية: NEW England, NEW York (State)
مستخلص: Summary: Flywheel energy storage system (FESS) needs to be operated within its allowable speed range because it will be shut down outside this range. Furthermore, the power supplied/absorbed by FESS is constrained by the associated power electronic interface. This article proposes supervisory adaptive predictive control (APC) scheme for flywheel energy storage system to enhance power system transient stability while addressing the constraints mentioned earlier. The supervisory adaptive predictive controller gives a reference power command signal to the inner control loop of FESS while ensuring the operation of FESS within its regime of operation. The gains of the inner control loop are optimized by employing Genetic Algorithm (GA). The constraints on the state of charge of FESS and power rating of the associated converter are explicitly included in the adaptive predictive controller formulation, which is usually done in an ad hoc manner. The performance of the proposed control strategy is evaluated under four scenarios: a step wind disturbance, realistic wind profile, doubly fed induction generator (DFIG) outage, and a severe symmetrical fault condition on modified New York/New England 16 machine 68‐bus power system. The validity of the adaptive predictive control based flywheel energy storage system (APC based FESS) in improving transient stability of power system is verified by the simulation studies carried out in MATLAB/Simulink environment. [ABSTRACT FROM AUTHOR]
Copyright of International Journal of Energy Research is the property of Hindawi Limited and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:0363907X
DOI:10.1002/er.7600