دورية أكاديمية

Potential bias in NMR relaxation data introduced by peak intensity analysis and curve fitting methods.

التفاصيل البيبلوغرافية
العنوان: Potential bias in NMR relaxation data introduced by peak intensity analysis and curve fitting methods.
المؤلفون: Viles, John H., Duggan, Brendan M., Zaborowski, Eduardo, Schwarzinger, Stephan, Huntley, James J. A., Kroon, Gerard J. A., Dyson, H. Jane, Wright, Peter E.
المصدر: Journal of Biomolecular NMR; Sep2001, Vol. 21 Issue 1, p1-9, 9p
مصطلحات موضوعية: SPECTRUM analysis, MOLECULAR biology, BIOMOLECULES, RELAXATION (Nuclear physics), RELAXATION phenomena, BIOPHYSICS
مستخلص: We present an evaluation of the accuracy and precision of relaxation rates calculated using a variety of methods, applied to data sets obtained for several very different protein systems. We show that common methods of data evaluation, such as the determination of peak heights and peak volumes, may be subject to bias, giving incorrect values for quantities such as R1 and R2. For example, one common method of peak-height determination, using a search routine to obtain the peak-height maximum in successive spectra, may be a source of significant systematic error in the relaxation rate. The alternative use of peak volumes or of a fixed coordinate position for the peak height in successive spectra gives more accurate results, particularly in cases where the signal/noise is low, but these methods have inherent problems of their own. For example, volumes are difficult to quantitate for overlapped peaks. We show that with any method of sampling the peak intensity, the choice of a 2- or 3-parameter equation to fit the exponential relaxation decay curves can dramatically affect both the accuracy and precision of the calculated relaxation rates. In general, a 2-parameter fit of relaxation decay curves is preferable. However, for very low intensity peaks a 3 parameter fit may be more appropriate. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Biomolecular NMR is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:09252738
DOI:10.1023/A:1011966718826