دورية أكاديمية

Hybrid Multi-Channel EEG Filtering Method for Ocular and Muscular Artifact Removal Based on the 3D Spline Interpolation Technique.

التفاصيل البيبلوغرافية
العنوان: Hybrid Multi-Channel EEG Filtering Method for Ocular and Muscular Artifact Removal Based on the 3D Spline Interpolation Technique.
المؤلفون: Abidi, Afef, Nouira, Ibtihel, Assali, Ines, Saafi, Mohamed Ali, Bedoui, Mohamed Hedi
المصدر: Computer Journal; May2022, Vol. 65 Issue 5, p1257-1271, 15p
مصطلحات موضوعية: INDEPENDENT component analysis, INTERPOLATION, SIGNAL-to-noise ratio, SUPPORT vector machines, BIOMEDICAL signal processing, AUTOMATIC classification, ELECTROENCEPHALOGRAPHY, MAXIMA & minima
مستخلص: The present work develops a novel hybrid method for ocular and muscular artifact removal from electroencephalography (EEG) signals, EFICA-TQWT. It is a combination of efficient fast independent component analysis (EFICA) method with the tunable Q-factor wavelet transform (TQWT). The main contribution of this paper is to apply the 3D interpolation method in the filtering system. Three EEG datasets are used in this work, two healthy and one epileptic. The choice of subjects for each dataset is made with the help of an expert in physiology. The selection criterion adopted is the presence of muscular and ocular artifacts in the processed recordings. First, a noisy channel automatic classification is performed by the support vector machine (SVM) with radial basis function in order to delete the signal(s) corresponding to the noisiest channel(s) from each EEG recording. The results of the automatic classification by the SVM were compared with those found by the expert's classification. An accuracy of 97.45%, a sensitivity of 86.66% and a 100% specificity are provided by the SVM classification. The hybrid method of artifact removal will be applied on the rest of the EEG channels of international 10/20 system for each subject. Then, a reconstruction of the eliminated channel signal(s) will be performed in order to obtain a well-filtered signal. The proposed filtering process is evaluated by calculating the mean squared error (MSE) and the signal to noise ratio (SNR). Both for the healthy and pathological EEG datasets, a comparative study of the proposed method (EFICA-TQWT) and other filtering techniques (Fast-ICA, DWT, TQWT and EFICA) is generated. The EFICA-TQWT method gave the best results with a minimum of MSE and a maximum of SNR, more particularly in the case of the application of the 3D interpolation method. Besides, in order to optimize the computing time of the proposed system, a parallel implementation of this filtering system is developed based on graphical processing units using compute unified device architecture. [ABSTRACT FROM AUTHOR]
Copyright of Computer Journal is the property of Oxford University Press / USA and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00104620
DOI:10.1093/comjnl/bxaa175