Development and deployment of cyclical focal muscle vibration system to improve walking performance in multiple sclerosis.

التفاصيل البيبلوغرافية
العنوان: Development and deployment of cyclical focal muscle vibration system to improve walking performance in multiple sclerosis.
المؤلفون: Hardin, Elizabeth C., Bailey, Stephanie Nogan, Kobetic, Rudolf, Lombardo, Lisa M., Foglyano, Kevin M., Schnellenberger, John R., Selkirk, Stephen M.
المصدر: Journal of Medical Engineering & Technology; Jul2022, Vol. 46 Issue 5, p393-401, 9p
مصطلحات موضوعية: KNEE, ANKLE, MULTIPLE sclerosis, HEART rate monitors, BLOOD pressure, WALKING speed, HEART rate monitoring
مستخلص: Vibration, a potent mechanical stimulus for activating muscle spindle primary afferents, may improve gait performance in persons with multiple sclerosis (MS), but has yet to be developed and deployed for multiple leg muscles with application during walking training. This study explored the development of a cyclic focal muscle vibration (FMV) system, and the deployment feasibility to correct MS walking swing phase deficits in order to determine whether this intervention warrants comprehensive study. The system was deployed during twelve, two-hour sessions of walking with cyclic FMV over six weeks. Participants served as their own control. Blood pressure, heart rate, walking speed, kinematics (peak hip, knee and ankle angles during swing), toe clearance, and step length were measured before and after deployment with blood pressure and heart rate monitored during deployment. During system deployment, there were no untoward sensations and physiological changes in blood pressure and heart rate, and volitional improvements were found in walking speed, improved swing phase kinematics, toe clearance and step length. This FMV training system was developed and deployed to improve joint flexion during walking in those with MS, and it demonstrated feasibility and benefits. Further study will determine the most effective vibration frequency and dose, carryover effects, and those most likely to benefit from this intervention. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Medical Engineering & Technology is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)