Assess critical tasks in postoperative spine stereotactic radiation therapy in presence of high density implants using a robotic radiotherapy device.

التفاصيل البيبلوغرافية
العنوان: Assess critical tasks in postoperative spine stereotactic radiation therapy in presence of high density implants using a robotic radiotherapy device.
المؤلفون: Henzen, Dominik, Schmidhalter, Daniel, Guyer, Gian, Stenger-Weisser, Anna, Ermiş, Ekin, Poel, Robert, Deml, Moritz Caspar, Fix, Michael Karl, Manser, Peter, Aebersold, Daniel Matthias, Hemmatazad, Hossein
المصدر: Journal of Radiosurgery & SBRT; 2022 Supplement, Vol. 8, p52-53, 2p
مصطلحات موضوعية: SPINE, RADIOTHERAPY, IMAGE registration, SPINAL surgery, ROBOTICS, COMPUTED tomography, DENSITY
مستخلص: Purpose: High density materials that are used in stabilization hardware potentially pose an issue regarding postoperative radiation therapy. This work investigates radiation therapy workflow steps in situations where hybrid implants consisting of titanium and carbon-fiber-composites (CFP-T) were used for stabilization and the radiation therapy is delivered using a robotic device. Methods: To investigate the quality of the image registration and delineation, these tasks were carried out using CT images from two patients with CFP-T implants in place. Treatment plans were created on an anthropomorphic phantom equipped with CFP-T spine stabilization to assess the accuracy of the calculated dose distributions. The phantom allows to measure the dose distribution near to the high density material using radiochromic film. Furthermore, a regular machine QA end-to-end (E2E) test was modified to test the image guidance procedure for the anthropomorphic phantom. Results: It was possible to delineate the patient cases with the CFP-T implants according to international consensus. The gamma passing rates of the comparison between the calculated and measured dose distributions were above 97% using the following criteria: 5% (of the maximal dose), 1 mm with 20% dose threshold. The modified E2E test was as accurate as the unmodified standard tests (targeting accuracy < 0.95 mm). Conclusion: No critical impediments regarding postoperative spine irradiations in presence of CFP-T implants were identified in this work. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Radiosurgery & SBRT is the property of Old City Publishing, Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index