العنوان: Metabolite-Specific Echo Planar Imaging for Preclinical Studies with Hyperpolarized 13 C-Pyruvate MRI.
المؤلفون: Sahin, Sule I., Ji, Xiao, Agarwal, Shubhangi, Sinha, Avantika, Mali, Ivina, Gordon, Jeremy W., Mattingly, Mark, Subramaniam, Sukumar, Kurhanewicz, John, Larson, Peder E. Z., Sriram, Renuka
المصدر: Tomography: A Journal for Imaging Research; Apr2023, Vol. 9 Issue 2, p736-749, 14p
مصطلحات موضوعية: ECHO-planar imaging, DIAGNOSTIC imaging, MAGNETIC resonance imaging, RENAL cell carcinoma, PYRUVATES, SPATIAL resolution, DOCETAXEL
مستخلص: Metabolite-specific echo-planar imaging (EPI) sequences with spectral–spatial (spsp) excitation are commonly used in clinical hyperpolarized [1-13C]pyruvate studies because of their speed, efficiency, and flexibility. In contrast, preclinical systems typically rely on slower spectroscopic methods, such as chemical shift imaging (CSI). In this study, a 2D spspEPI sequence was developed for use on a preclinical 3T Bruker system and tested on in vivo mice experiments with patient-derived xenograft renal cell carcinoma (RCC) or prostate cancer tissues implanted in the kidney or liver. Compared to spspEPI sequences, CSI were found to have a broader point spread function via simulations and exhibited signal bleeding between vasculature and tumors in vivo. Parameters for the spspEPI sequence were optimized using simulations and verified with in vivo data. The expected lactate SNR and pharmacokinetic modeling accuracy increased with lower pyruvate flip angles (less than 15°), intermediate lactate flip angles (25° to 40°), and temporal resolution of 3 s. Overall SNR was also higher with coarser spatial resolution (4 mm isotropic vs. 2 mm isotropic). Pharmacokinetic modelling used to fit kPL maps showed results consistent with the previous literature and across different sequences and tumor xenografts. This work describes and justifies the pulse design and parameter choices for preclinical spspEPI hyperpolarized 13C-pyruvate studies and shows superior image quality to CSI. [ABSTRACT FROM AUTHOR]
Copyright of Tomography: A Journal for Imaging Research is the property of MDPI and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:23791381
DOI:10.3390/tomography9020059