دورية أكاديمية

Blood Flow Restriction Training in Clinical Rehabilitation: Occlusion Pressure Methods Relative to the Limb Occlusion Pressure.

التفاصيل البيبلوغرافية
العنوان: Blood Flow Restriction Training in Clinical Rehabilitation: Occlusion Pressure Methods Relative to the Limb Occlusion Pressure.
المؤلفون: Chulvi-Medrano, Iván, Cortell-Tormo, Juan Manuel, Hernández-Sánchez, Sergio, Picón-Martínez, Moisés, Rolnick, Nicholas
المصدر: Journal of Sport Rehabilitation; May2023, Vol. 32 Issue 4, p361-368, 8p, 2 Charts, 1 Graph
مصطلحات موضوعية: BLOOD pressure, ARTERIAL occlusions, RESISTANCE training, TOURNIQUETS, SKELETAL muscle, ANALYSIS of variance, BLOOD flow restriction training, RESEARCH methodology, LEG, BLOOD circulation, MUSCLE strength, DOPPLER ultrasonography, REPEATED measures design, REHABILITATION, BLOOD pressure measurement, HEMODYNAMICS, DATA analysis software
مستخلص: Context: Resistance training with blood flow restriction (BFR) has increased in clinical rehabilitation due to the substantial benefits observed in augmenting muscle mass and strength using low loads. However, there is a great variability of training pressures for clinical populations as well as methods to estimate it. The aim of this study was to estimate the percentage of maximal BFR that could result by applying different methodologies based on arbitrary or individual occlusion levels using a cuff width between 9 and 13 cm. Design: A secondary analysis was performed on the combined databases of 2 previous larger studies using BFR training. Methods: To estimate these percentages, the occlusion values needed to reach complete BFR (100% limb occlusion pressure [LOP]) were estimated by Doppler ultrasound. Seventy-five participants (age 24.32 [4.86] y; weight: 78.51 [14.74] kg; height: 1.77 [0.09] m) were enrolled in the laboratory study for measuring LOP in the thigh, arm, or calf. Results: When arbitrary values of restriction are applied, a supra-occlusive LOP between 120% and 190% LOP may result. Furthermore, the application of 130% resting brachial systolic blood pressure creates a similar occlusive stimulus as 100% LOP. Conclusions: Methods using 100 mm Hg and the resting brachial systolic blood pressure could represent the safest application prescriptions as they resulted in applied pressures between 60% and 80% LOP. One hundred thirty percent of the resting brachial systolic blood pressure could be used to indirectly estimate 100% LOP at cuff widths between 9 and 13 cm. Finally, methodologies that use standard values of 200 and, 300 mm Hg far exceed LOP and may carry additional risk during BFR exercise. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Sport Rehabilitation is the property of Human Kinetics Publishers, Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:10566716
DOI:10.1123/jsr.2022-0240