دورية أكاديمية

Intrinsic factors contributing to elevated intra-abdominal pressure.

التفاصيل البيبلوغرافية
العنوان: Intrinsic factors contributing to elevated intra-abdominal pressure.
المؤلفون: Niederauer, Stefan, Hunt, Grace, Foreman, K. Bo, Merryweather, Andrew, Hitchcock, Robert
المصدر: Computer Methods in Biomechanics & Biomedical Engineering; Jun2023, Vol. 26 Issue 8, p941-951, 11p
مصطلحات موضوعية: INTRA-abdominal pressure, PELVIC floor, PELVIC floor disorders, RESPIRATION, PARTIAL least squares regression, MOTION capture (Human mechanics), ABDOMINAL muscles
مستخلص: Pelvic floor disorders affect 24% of US women, and elevated intra-abdominal pressure may cause pelvic injury through musculoskeletal strain. Activity restrictions meant to reduce pelvic strain after traumatic events, such as childbirth, have shown little benefit to patients. Reported high variability in abdominal pressure suggests that technique plays a substantial role in pressure generation. Understanding these techniques could inform evidence-based recommendations for protective pelvic care. We hypothesized use of a motion-capture methodology could identify four major contributors to elevated pressure: gravity, acceleration, abdominal muscle contraction, and respiration. Twelve women completed nineteen activities while instrumented for whole body motion capture, abdominal pressure, hip acceleration, and respiration volume. Correlation and partial least squares regression were utilized to determine primary technique factors that increase abdominal pressure. The partial least squares model identified two principal components that explained 59.63% of relative intra-abdominal pressure variability. The first component was primarily loaded by hip acceleration and relative respiration volume, and the second component was primarily loaded by flexion moments of the abdomen and thorax. While reducing abdominal muscle use has been a primary strategy in protective pelvic floor care, the influence of hip acceleration and breathing patterns should be considered with similar importance in future work. [ABSTRACT FROM AUTHOR]
Copyright of Computer Methods in Biomechanics & Biomedical Engineering is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:10255842
DOI:10.1080/10255842.2022.2100220