Experimental study on load sharing characteristics of long-short CFG pile composite foundation adjacent to rigid retaining wall rotating about its base.

التفاصيل البيبلوغرافية
العنوان: Experimental study on load sharing characteristics of long-short CFG pile composite foundation adjacent to rigid retaining wall rotating about its base.
المؤلفون: Uge, Bantayehu Uba, Yuan-Cheng Guo
المصدر: Journal of Engineering Research (2307-1877); Mar2023, Vol. 11 Issue 1B, p125-135, 11p
مصطلحات موضوعية: BUILDING foundations, RETAINING walls, BASES (Architecture), CITIES & towns, SHARING, BEARING capacity of soils
مستخلص: Practicing geoengineers and researchers generally consider the load sharing behavior in multi-type pile composite foundation as an important design aspect. On the other hand, due to urbanization, such foundation system in cities will inevitably appear next to supported excavation. This paper discusses the result from relatively largescale indoor experiment conducted to investigate the load sharing behavior of loaded long-short CFG pile composite foundation behind a neighboring rigid retaining wall undergoing rotation around the bottom. It was found that with progression of wall movement, the hidden load from soil displacement was borne by the piles with marked reduction in soil load sharing. At the end of wall rotation, the percentage of long piles’ head load increment needed to arrive at a new static equilibrium was about 12.57~32.22% while the end bearing increased by more than 97%. The consequences on the short piles, however, were manifested with an increasing pile head (13.42%) and toe (28.9%) load for the pile far from the wall whereas the closest one experienced a certain increment up to 15×10-4rad wall rotation and finally the head load and end bearing decreased to 8.28% and 12.63%, respectively. The 3D numerical back analysis conducted using FE software ABAQUS yielded the pile – soil stress ratio lower than the value obtained from the experiment but provided great insight into pile settlement characteristics during wall rotation. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Engineering Research (2307-1877) is the property of Kuwait University, Academic Publication Council and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:23071877
DOI:10.36909/jer.13241