دورية أكاديمية

Response of G-NUMEN LaBr 3 (Ce) Detectors to High Counting Rates.

التفاصيل البيبلوغرافية
العنوان: Response of G-NUMEN LaBr 3 (Ce) Detectors to High Counting Rates.
المؤلفون: Gandolfo, Elisa Maria, Oliveira, José Roberto Brandao, Campajola, Luigi, Pierroutsakou, Dimitra, Boiano, Alfonso, Agodi, Clementina, Cappuzzello, Francesco, Carbone, Diana, Cavallaro, Manuela, Ciraldo, Irene, Calvo, Daniela, Delaunay, Franck, Eke, Canel, Longhitano, Fabio, Medina, Nilberto, Moralles, Mauricio, Sartirana, Diego, Sharma, Vijay Raj, Spatafora, Alessandro, Toufen, Dennis
المصدر: Instruments (2410-390X); Sep2023, Vol. 7 Issue 3, p28, 17p
مصطلحات موضوعية: NEUTRINOLESS double beta decay, DETECTORS, MAGNETIC spectrometer, GAMMA rays, CONTRAST-enhanced magnetic resonance imaging, FOCAL planes, NUCLEAR matrix
مستخلص: The G-NUMEN array is the future gamma spectrometer of the NUMEN experiment (nuclear matrix element for neutrinoless double beta decay), to be installed around the object point of the MAGNEX magnetic spectrometer at the INFN-LNS laboratory. This project aims to explore double-charge exchange (DCE) reactions in order to obtain crucial information about neutrinoless double beta decay (0νββ). The primary objective of the G-NUMEN array is to detect the gamma rays emitted from the de-excitation of the excited states that are populated via DCE reactions with a good energy resolution and detection efficiency, amidst a background composed of the transitions from competing reaction channels with far higher cross sections. To achieve this, G-NUMEN signals will be processed in coincidence with those generated by the detection of reaction ejectiles by the MAGNEX focal plane detector (FPD). Under the expected experimental conditions, G-NUMEN detectors will operate at high counting rates, of the order of hundreds of kHz per detector, while maintaining excellent energy and timing resolutions. The complete array will consist of over 100 LaBr3(Ce) scintillators. Initial tests were conducted on the first detectors of the array, allowing for the determination of their performance at high rates. [ABSTRACT FROM AUTHOR]
Copyright of Instruments (2410-390X) is the property of MDPI and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:2410390X
DOI:10.3390/instruments7030028