دورية أكاديمية

Quantitative Measurement of Pharyngeal Dimensions During Drug‐induced Sleep Endoscopy for Oral Appliance Outcome.

التفاصيل البيبلوغرافية
العنوان: Quantitative Measurement of Pharyngeal Dimensions During Drug‐induced Sleep Endoscopy for Oral Appliance Outcome.
المؤلفون: Van den Bossche, Karlien, Van de Perck, Eli, Vroegop, Anneclaire V., Verbraecken, Johan A., Braem, Marc J., Dieltjens, Marijke, Op de Beeck, Sara, Vanderveken, Olivier M.
المصدر: Laryngoscope; Dec2023, Vol. 133 Issue 12, p3619-3627, 9p
مستخلص: Objective: To quantitatively investigate the effect of mandibular advancement devices (MADs) on pharyngeal airway dimensions in a transverse plane as measured during drug‐induced sleep endoscopy (DISE). Methods: Data from 56 patients, treated with MAD at 75% maximal protrusion and with baseline Apnea‐Hypopnea Index ≥10 events/h, were analyzed. For each patient, three snapshots were selected from DISE video footage at baseline, with MAD presence, and during chin lift, resulting in 498 images (168/168/162, baseline/MAD/chin lift). Cross‐sectional areas, anteroposterior (AP) and laterolateral (LL) dimensions on both retroglossal and retro‐epiglottic levels were measured. To define the effect of MAD and chin lift on pharyngeal dimensions, linear mixed‐effect models were built. Associations between MAD treatment response and pharyngeal expansion (MAD/chin lift) were determined. Results: Significant differences were found between retroglossal cross‐sectional areas, AP, and LL dimensions at baseline and with MAD presence. At a retro‐epiglottic level, only LL dimensions differed significantly with MAD presence compared to baseline, with significant relation of LL expansion ratio to treatment response (p = 0.0176). After adjusting the response definition for the sleeping position, greater retroglossal expansion ratios were seen in responders (1.32 ± 0.48) compared to non‐responders (1.11 ± 0.32) (p = 0.0441). No significant association was found between response and pharyngeal expansion by chin lift. Conclusion: Our observations highlight the additional value of quantitative pharyngeal airway measurements during DISE with MAD presence in evaluating MAD treatment outcome. These findings demonstrate an increase in retroglossal airway dimensions during DISE, with MAD presence, and more pronounced increase in retroglossal expansion ratios in MAD treatment responders compared to non‐responders after sleeping position correction. Level of Evidence: 3 Laryngoscope, 133:3619–3627, 2023 [ABSTRACT FROM AUTHOR]
Copyright of Laryngoscope is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:0023852X