The Accuracy of Full-Arch Intraoral Optical Impressions (IOS): Clinical Pilot Study of the Influence of the Scan Strategy, Operator, and Intraoral Scanner.

التفاصيل البيبلوغرافية
العنوان: The Accuracy of Full-Arch Intraoral Optical Impressions (IOS): Clinical Pilot Study of the Influence of the Scan Strategy, Operator, and Intraoral Scanner.
المؤلفون: Cordaro, Matteo, Sailer, Irena, Zarauz, Cristina, Xinran Liu, Duygu Karasan
المصدر: International Journal of Prosthodontics; Nov/Dec2023, Vol. 36 Issue 6, p689-696, 8p
مصطلحات موضوعية: DENTAL impressions, DIGITAL dental impression systems, SCANNING systems, ROOT-mean-squares, DENTAL arch, PILOT projects, MACHINE learning
مستخلص: Purpose: To investigate the influence of a novel scanning strategy--using two new intraoral scanner devices with different operators--on the full-arch scanning accuracy for a dentate maxilla. Materials and Methods: Two scanning strategies, a test and a control strategy, were used to produce full-arch impressions of the dentate maxilla of a study patient. Two intraoral scanning (IOS) devices were used. Five expert operators performed a total of 40 scans. The scan time was recorded for each. A reference model was obtained from the patient's maxillary arch with an analog impression. The model was later scanned with a highprecision laboratory scanner to create a digital reference model (DRM). The scanning accuracy was analyzed with 3D-analysis software using a root mean square (RMS) calculation method, and qualitative analysis was executed using machine learning software. Results: The mean RMS result for the test strategy was 82.8 ± 16 µm compared to 81.5 ± 16 µm for the control strategy. The mean RMS results were 84.7 ± 15 µm for Primescan (PS) and 79.6 ± 17 µm for 3Shape (3S). As such, the scanning strategies and IOS devices did not influence the scanning accuracy. Yet, a significant difference was found when the two strategies' scanning times were compared (P = .001), as well as the IOS devices (P = .001). The operator was found to have no influence on the scanning strategy. Conclusions: The accuracy of digital impressions is not influenced by different strategies, devices, or operators, in contrast with the scanning time, which is influenced by both strategies and devices. [ABSTRACT FROM AUTHOR]
Copyright of International Journal of Prosthodontics is the property of Quintessence Publishing Company Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:08932174
DOI:10.11607/ijp.8113