Controlling a Below-the-Elbow Prosthetic Arm Using the Infinity Foot Controller.

التفاصيل البيبلوغرافية
العنوان: Controlling a Below-the-Elbow Prosthetic Arm Using the Infinity Foot Controller.
المؤلفون: Bishay, Peter L., Wilgus, Jack, Chen, RunRun, Valenzuela, Diego, Medina, Victor, Tan, Calvin, Ittner, Taylor, Caldera, Miguel, Rubalcava, Cristina, Safarian, Shaghik, Alfaro, Gerbert Funes, Gonzalez-Martinez, Alfredo, Gosparini, Matthew, Fuentes-Perez, Jose, Lima, Andy, Villalobos, Jonnathan, Solis, Abrahan
المصدر: Prosthesis (2673-1592); Dec2023, Vol. 5 Issue 4, p1206-1231, 26p
مصطلحات موضوعية: FOOT physiology, WRIST physiology, ARTIFICIAL limbs, GRIP strength, STRUCTURAL models, BIONICS, AMPUTEES, BODY movement, PROSTHESIS design & construction
مستخلص: Nowadays there are various prosthetic arm designs in the literature, the market, and CAD design websites, with different shapes, sizes, and degrees of freedom. Only limited options are available for controlling such prostheses. Prosthetic arm users reported muscle fatigue and unreliability when using the market-dominated myoelectric sensors. This work presents the "Infinity Foot Controller" as a new approach to control a five-finger below-the-elbow prosthetic arm with wrist rotation and bending capabilities. This foot control system receives user input from a custom insole and a sensor-controller unit placed alongside the user's shoe to perform various hand grips, gestures, and/or rotations. To demonstrate the new foot controller, a design of a 3D-printed below-the-elbow prosthetic arm, called the "Infinity Arm", is presented. This arm is suitable for gripping relatively lightweight objects and making hand gestures. It includes a wrist actuation system that permits 120° wrist rotation and 70° wrist extension and flexion. It also includes a haptic feedback system that utilizes fingertip force sensors to relay a vibratory response in an armband placed on the user's arm, giving the user a sense of touch. A proof-of-concept model was built to demonstrate the system and a testing procedure was proposed. [ABSTRACT FROM AUTHOR]
Copyright of Prosthesis (2673-1592) is the property of MDPI and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:26731592
DOI:10.3390/prosthesis5040084