دورية أكاديمية

Thoracic-Worn Accelerometers Detect Fatigue-Related Changes in Vertical Stiffness During Sprinting.

التفاصيل البيبلوغرافية
العنوان: Thoracic-Worn Accelerometers Detect Fatigue-Related Changes in Vertical Stiffness During Sprinting.
المؤلفون: Horsley, Benjamin J., Tofari, Paul J., Halson, Shona L., Kemp, Justin G., Johnston, Rich D., Cormack, Stuart J.
المصدر: Journal of Strength & Conditioning Research; Feb2024, Vol. 38 Issue 2, p283-289, 7p
مصطلحات موضوعية: CHEST (Anatomy), NEUROPHYSIOLOGY, CONFIDENCE intervals, RUNNING, WEARABLE technology, ACCELEROMETERS, MUSCLE fatigue, NEUROMUSCULAR system, DESCRIPTIVE statistics, FATIGUE (Physiology), SPRINTING, ALGORITHMS
مستخلص: Horsley, BJ, Tofari, PJ, Halson, SL, Kemp, JG, Johnston, RD, and Cormack, SJ. Thoracic-worn accelerometers detect fatiguerelated changes in vertical stiffness during sprinting. J Strength Cond Res 38(2): 283-289, 2024--Thoracic-mounted accelerometers are valid and reliable for analyzing gait characteristics and may provide the opportunity to assess running-related neuromuscular fatigue (NMF) during training and competition without the need for additional tests, such as a countermovement jump (CMJ). However, their sensitivity for detecting fatigue-related changes in gait across different speeds is unclear. We, therefore, assessed the changes in accelerometer-derived gait characteristics, including vertical stiffness (Kvert), following a repeated sprint protocol (RSP). Sixteen recreationally active subjects performed single and repeated CMJs on a force plate and 40 m run throughs overground at 3-4, 5-6, and 7-8 m·s21 pre-post a 123 40 mRSP. Gait characteristics (contact time, step frequency, step length, Kvert, etc.) were derived from an accelerometer contained within a global navigation satellite system unit on the thoracic spine using a validated algorithm. Changes in running gait and CMJ performance were assessed using a linear mixed-effects model (95% confidence interval [95% CI]; effect size [ES]). Significance was set at p < 0.05. A significant reduction in Kvert occurred at 7-8m·s21 following the RSP (28.51 kN·m21 [213.9, 23.11]; p 5 0.007; ES [95% CI] 5 20.39 [20.62, 20.15]) which coincided with a decreased jump height (20.03 m [20.04, 20.01]; p 5 0.002; ES [95% CI] 5 20.87 [21.41, 20.30]). However, all other gait characteristics were not significantly different irrespective of speed. Thoracic-worn accelerometers can detect changes in Kvert at 7-8 m·s21 which may be useful for monitoring NMF during sprinting. However, a RSP does not result in altered gait mechanics in subsequent running at lower speeds. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Strength & Conditioning Research is the property of Lippincott Williams & Wilkins and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:10648011
DOI:10.1519/jsc.0000000000004614