دورية أكاديمية

Distributions and number of drivers on real-time phase mapping associated with successful atrial fibrillation termination during catheter ablation for non-paroxysmal atrial fibrillation.

التفاصيل البيبلوغرافية
العنوان: Distributions and number of drivers on real-time phase mapping associated with successful atrial fibrillation termination during catheter ablation for non-paroxysmal atrial fibrillation.
المؤلفون: Riku, Shuro, Inden, Yasuya, Yanagisawa, Satoshi, Fujii, Aya, Tomomatsu, Toshiro, Nakagomi, Toshifumi, Shimojo, Masafumi, Okajima, Takashi, Furui, Koichi, Suga, Kazumasa, Suzuki, Susumu, Shibata, Rei, Murohara, Toyoaki
المصدر: Journal of Interventional Cardiac Electrophysiology; Mar2024, Vol. 67 Issue 2, p303-317, 15p
مستخلص: Background : Real-time phase mapping (ExTRa™) is useful in determining the strategy of catheter ablation for non-paroxysmal atrial fibrillation (AF). This study aimed to investigate the features of drivers of AF associated with its termination during ablation. Methods: Thirty-six patients who underwent catheter ablation for non-paroxysmal AF using online real-time phase mapping (ExTRa™) were enrolled. A significant AF driver was defined as an area with a non-passively activated ratio of ≥ 50% on mapping analysis in the left atrium (LA). All drivers were simultaneously evaluated using a low-voltage area, complex fractionated atrial electrogram (CFAE), and rotational activity by unipolar electrogram analysis. The electrical characteristics of drivers were compared between patients with and without AF termination during the procedure. Results: Twelve patients achieved AF termination during the procedure. The total number of drivers detected on the mapping was significantly lower (4.4 ± 1.6 vs. 7.4 ± 3.8, p = 0.007), and the drivers were more concentrated in limited LA regions (2.8 ± 0.9 vs. 3.9 ± 1.4, p = 0.009) in the termination group than in the non-termination group. The presence of drivers 2–6 with limited (≤ 3) LA regions showed a tenfold increase in the likelihood of AF termination, with 83% specificity and 67% sensitivity. Among 231 AF drivers, the drivers related to termination exhibited a greater overlap of CFAE (56.8 ± 34.1% vs. 39.5 ± 30.4%, p = 0.004) than the non-related drivers. The termination group showed a trend toward a lower recurrence rate after ablation (p = 0.163). Conclusions: Rotors responsible for AF maintenance may be characterized in cases with concentrated regions and fewer drivers on mapping. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Interventional Cardiac Electrophysiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:1383875X
DOI:10.1007/s10840-023-01588-8