Experimental Analysis of an Innovative Double Strap Joint Splicing of GFRP Bars by NSM Methods for Strengthening RC Beams.

التفاصيل البيبلوغرافية
العنوان: Experimental Analysis of an Innovative Double Strap Joint Splicing of GFRP Bars by NSM Methods for Strengthening RC Beams.
المؤلفون: Ranković, Slobodan, Folić, Radomir, Zorić, Andrija, Vacev, Todor, Petrović, Žarko, Kovačević, Dušan
المصدر: Periodica Polytechnica: Civil Engineering; 2024, Vol. 68 Issue 1, p185-196, 12p
مصطلحات موضوعية: CONCRETE beams, BENDING moment, REINFORCED concrete, FAILURE mode & effects analysis, GLASS fibers
مستخلص: The double strap joint splicing of glass fiber reinforced polymer (GFRP) bars for reinforced concrete (RC) beams strengthening, applying the near surface mounting (NSM) method, has been proposed in the paper. The proposed method consists of application of the supplementary GFRP bars symmetrically positioned in the cut-off zone of the main GFRP reinforcement. The performances of this splicing method have been experimentally tested for the most unfavorable case of the GFRP reinforcement cut-off in the maximal bending moment zones. During the experiment, the varied parameter has been overlapping length of the bars, taking values of 20Ø and 40Ø. Evaluation of the splicing technique is done comparing the experimental results with the results of the behavior of beams strengthened by GFRP bars without cut-off and with cut-off, but without splicing. Experimental research encompassed analysis of strength, stiffness, ductility, crack pattern, strains in the steel, GFRP reinforcement and concrete, and the failure modes of the beams. It has been shown that in case of the cut-off of the GFRP bar, strengthening effectivity decreases for 39%, and that in the case of bypassing the cut-off using double strap 20Ø and 40Ø long, strengthening effectivity decreased 23%, and 14% respectively, compared to the beam without GFRP bar cut-off. Using extrapolation, it has been shown that double strap with length of 60Ø provided strength equivalent to the case without cut-off. The result of application of this splicing method of the additional GFRP bars is significant increase of strength and serviceability of the strengthened RC beams. [ABSTRACT FROM AUTHOR]
Copyright of Periodica Polytechnica: Civil Engineering is the property of Periodica Polytechnica and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:05536626
DOI:10.3311/PPci.22681