DETERMINING FEATURES IN THE APPLICATION OF REDUNDANCY FOR THE THERMISTOR CUBIC TRANSFORMATION FUNCTION USING COMPUTER SIMULATION.

التفاصيل البيبلوغرافية
العنوان: DETERMINING FEATURES IN THE APPLICATION OF REDUNDANCY FOR THE THERMISTOR CUBIC TRANSFORMATION FUNCTION USING COMPUTER SIMULATION.
Alternate Title: ВИЗНАЧЕННЯ ОСОБЛИВОСТЕЙ ЗАСТОСУВАННЯ НАДЛИШКОВОСТІ ПРИ КУБІЧНІЙ ФУНКЦІЇ ПЕРЕТВОРЕННЯ ТЕРМОРЕЗИСТОРА ЗА ДОПОМОГОЮ КОМП’ЮТЕРНОГО МОДЕЛЮВАННЯ. (Ukrainian)
المؤلفون: Shcherban, Volodymyr, Korohod, Hanna, Kolysko, Oksana, Kyrychenko, Anton, Shcherban, Yury, Shchutska, Ganna
المصدر: Eastern-European Journal of Enterprise Technologies; 2024, Vol. 127 Issue 5, p33-40, 8p
مصطلحات موضوعية: THERMISTORS, COMPUTER simulation, HIGH temperatures, TEMPERATURE measurements
مستخلص: The object of research is the process of temperature measurement with a platinum thermistor. We have conducted studies on the cubic transformation function of the thermistor when using redundancy that yielded the equation of redundant measurements of the desired temperature. Owing to this, it became possible to directly apply the resulting equation without additional measures to linearize the function of the thermistor transformation. In addition, the obtained value of the desired temperature does not depend on the values of the parameters of the cubic transformation function and their deviations from the nominal values. Experimental studies have proven that the value of the normalized temperature T0 has a greater influence on the result of redundant measurements and the value of the normalized temperature ΔT on the entire range of measured temperatures Tx is almost unaffected. The best accuracy results (value of relative error δ=0.02 %) were obtained at T0 values lower than –60 °C. When the error of reproduction of normalized temperatures increased from ±0.02 °C to ±0.1 °C, the best accuracy results (value of relative error δ=0.06 %) were obtained at values of normalized temperature T0 below –130 °C. Analysis of results of the absolute error ΔT revealed that with an error of reproduction of normalized temperatures of ±0.02 °C and at T0=–180 °C, its value does not exceed 0.02 °C, that is, it is within the error of reproduction of normalized temperatures. This allows us to state that it is recommended to use sources of standardized temperatures of high accuracy during measurement control. Thus, there are reasons to assert the prospect for redundant measurements when directly measuring temperature with a thermistor with a cubic transformation function with high accuracy. [ABSTRACT FROM AUTHOR]
Copyright of Eastern-European Journal of Enterprise Technologies is the property of PC TECHNOLOGY CENTER and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:17293774
DOI:10.15587/1729-4061.2024.297619