دورية أكاديمية

Radiation doses of medical radiation workers performing low-dose-rate brachytherapy with 198Au grains and 192Ir pins for patients with oral cancers.

التفاصيل البيبلوغرافية
العنوان: Radiation doses of medical radiation workers performing low-dose-rate brachytherapy with 198Au grains and 192Ir pins for patients with oral cancers.
المؤلفون: Konishi, Masaru, Shimabukuro, Kiichi, Hirokawa, Junichi, Sadatoki, Takashi, Katsuta, Tsuyoshi, Imano, Nobuki, Nishibuchi, Ikuno, Murakami, Yuji, Kakimoto, Naoya
المصدر: Oral Radiology; Apr2024, Vol. 40 Issue 2, p234-241, 8p
مصطلحات موضوعية: MOUTH tumors, FISHER exact test, RADIOISOTOPE brachytherapy, RADIATION dosimetry, CANCER patients, DESCRIPTIVE statistics, CHI-squared test, MANN Whitney U Test, ALLIED health personnel, DENTISTS, MEDICAL radiology, RADIATION doses, PHYSICIANS, TONGUE tumors, DATA analysis software
مستخلص: Objectives: Low-dose-rate brachytherapy (LDR-BT) with 198Au grains and 192Ir pins is an essential treatment option for oral cancer due to its high rate of local control and low invasiveness. However, the radiation exposure of medical radiation workers is concerning. Thus, we aimed to determine the radiation dose delivered to medical radiation workers during LDR-BT using 198Au grains and 192Ir pins for oral cancer. Methods: Thirty-two patients with oral cancer underwent 198Au grain interstitial LDR-BT between June 2016 and May 2023, and 23 patients with tongue cancer underwent 192Ir pin interstitial LDR-BT between March 2015 and November 2017 at our hospital. Dosimetry was performed by attaching a dosimeter to the chest pocket of the operator and assistant during 198Au grain or 192Ir pin LDR-BT. Since the operator also loads 198Au grains into the implantation device, the operator's radiation dose includes the dose received during this preparation. Results: Mean radiation doses of the operators with 198Au grain and 192Ir pin LDR-BT were 165.8 and 211.2 μSv, respectively. Statistically significant differences between the radioactive sources of 198Au grain and 192Ir pin LDR-BT were observed (p = 0.0459). The mean radiation doses of the assistants with 198Au grain and 192Ir pin LDR-BT were 92.0 and 162.0 μSv, respectively. Statistically significant differences were observed between the radioactive sources of 198Au grains and 192Ir pin LDR-BT (p = 0.0003). Conclusions: Regarding radioactive source differences, 192Ir pin LDR-BT resulted in higher doses delivered to medical radiation workers than 198Au grain LDR-BT. [ABSTRACT FROM AUTHOR]
Copyright of Oral Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:09116028
DOI:10.1007/s11282-023-00728-0